9
|
Electrical installation
Installer reference guide
131
EPRA14~18D + ETSH/X(B)16P30+50E
Daikin Altherma 3 H HT ECH₂O
4P679467-1B – 2022.09
A
B
B
5 6
X 2M
1
N/- L/+
Space C/H
On/OFF output
Max. load
0,3 A - 230 V AC
1 A - 5 V DC
5
6
A
3
Fix the cable with cable ties to the cable tie mountings. General information,
see
"9.3.1 To connect the electrical wiring to the indoor unit"
118].
9.3.10 To connect the changeover to external heat source
INFORMATION
Bivalent is only possible in case of 1 leaving water temperature zone with:
▪
room thermostat control, OR
▪
external room thermostat control.
Wires: 2×0.75 mm²
Maximum load: 0.3 A, 230 V AC
Maximum load: 1 A, 5 V DC
[9.C]
Bivalent
1
Open the following (see
"7.2.6 To open the indoor unit"
1
User interface panel
1
3
4
2
2
Switch box
3
Switch box cover
4
Top cover
2
Connect the changeover to external heat source cable to the appropriate
terminals as shown in the illustration below.