8/19
Breadcrumb
Setting name
Range, step
Default value
Field settings table
9.1.A
[0-07]
R/W
10~25°C, step: 1°C
20°C
└─
Tank
9.1.B.1
[6-0D]
R/W
0: Reheat only
3 scheduled reheat
9.1.B.2
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
9.1.B.3
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.4
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.5
[6-08]
R/W
2~20°C, step: 1°C
10°C
└─
Domestic hot water
9.2.1
[E-05]
[E-06]
[E-07]
R/O
Integrated'
9.2.2
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.2.4
[D-07]
R/W
0: No
1: Yes (DHW)
2: Yes (DHW + SH)
└─
Back up heater
9.3.1
[E-03]
R/W
0: no heater (*7)
2: 3V (*4)
3: 6V (*5)
4: 9W (*6)
9.3.2
[5-0D]
R/W
0: 230V, 1~ (*4, *5, *7)
2: 400V, 3~ (*6)
9.3.3
[4-0A]
R/W (*5,
*6, *7)
R/O (*4)
0: 1 (*4, *7)
1: 1/1+2 (*5, *6)
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.3.4
[6-03]
R/W
0~10kW, step: 0,2kW
0kW
2kW (*5)
3kW (*4, *6, *7)
9.3.5
[6-04]
R/W (*5,
*6)
R/O (*4,
*7)
0~10kW, step: 0,2kW
0kW (*4)
3kW (*7)
4kW (*5)
6kW (*6)
9.3.6
[5-00]
R/W
0: No (*10)
1: Yes (*9)
9.3.7
[5-01]
R/W
-15~35°C, step: 1°C
0°C
9.3.8
[4-00]
R/W
0: Restricted
1: Allowed
2: Only DHW
└─
Booster heater
9.4.1
[6-02]
R/W
0~10kW, step: 0,2kW
0kW
9.4.3
[8-03]
R/W
20~95 min, step: 5 min
50 min
9.4.4
[4-03]
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
└─
Emergency
9.5.1
[4-06]
R/W
0: Manual
1: Automatic
2: Auto SH reduced/ DHW ON
3: Auto SH reduced/ DHW OFF
4: Auto SH normal/ DHW OFF
Equilibrium: Deactivate backup heater (or external backup heat
source in case of a bivalent system) above the equilibrium
temperature for space heating?
Equilibrium temperature
Operation
Capacity
BSH eco timer
Operation
Emergency
DHW pump
Solar
BUH type
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
Reheat hysteresis
Domestic hot water
Low ambient temp. for LWT add zone cooling WD curve.
4P681797-1B - 2022.09
(*1) *X*_(*2) *H*_(*3) *B*_(*4) *EKECBUA*3V_
(*5) *EKECBUA*6V_(*6) *EKECBUA*9W_(*7) BUH less_
(*8) 300L tank_(*9) E_(*10) E7