You can set the tank temperature schedule using the schedule screen. For more
information about this screen, see
"10.3.7 Schedule screen: Example"
154].
Heat up mode
The domestic hot water can be prepared in 2 different ways. They differ from each
other by the way the desired tank temperature is set and how the unit acts upon it.
#
Code
Description
[5.6]
[6-0D]
Heat up mode
:
▪
0:
Reheat
only
: The storage tank
temperature is always kept at the setpoint
selected in the tank setpoint screen.
▪
3:
Scheduled reheat
: The storage tank
temperature varies according to the tank
temperature schedule.
See the operation manual for more details.
Disinfection
The disinfection function disinfects the water inside the domestic hot water heat
exchanger coil by periodically heating the storage tank to a specific temperature.
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
#
Code
Description
[5.7.1]
[2‑01]
Activation
:
▪
0:
No
▪
1:
Yes
[5.7.2]
[2‑00]
Operation day
:
▪
0:
Every day
▪
1:
Monday
▪
2:
Tuesday
▪
3:
Wednesday
▪
4:
Thursday
▪
5:
Friday
▪
6:
Saturday
▪
7:
Sunday
[5.7.3]
[2‑02]
Start time
[5.7.4]
[2‑03]
Tank setpoint
:
60°C
[5.7.5]
[2‑04]
Duration
:
40~60 minutes