9
|
Electrical installation
Installer reference guide
79
EPGA11~16DAV3(7) + EA23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09
In case of normal kWh rate power supply
X1M
X2M
X5M
A5P
X11YB
X1A
1 2 3
1 2 3
a
X11Y
X11YA
1 2 3
a
Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
Connect X11Y to X11YB.
X1M
X2M
X5M
A5P
X11Y
X11YB
X1A
1 2 3
1
N L
N L
2 3
S1S
a
b
c
X11YA
5
1 2 3
6
9 10
a
Interconnection cable (=main power supply)
b
Normal kWh rate power supply
c
Preferential power supply contact
2
Fix the cables with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect X11Y to X11YB. The necessity
of separate normal kWh rate power supply to indoor unit (b) X2M/5+6 depends on
the type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪
if preferential kWh rate power supply is interrupted when active, OR
▪
if no power consumption of the indoor unit is allowed at the preferential kWh
rate power supply when active.