2/10
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Room
└─
Antifrost
1.4.1
[2-06]
R/W
0: Disabled
1: Enabled
1.4.2
[2-05]
R/W
4~16°C, step: 1°C
8°C
└─
Setpoint range
1.5.1
[3-07]
R/W
12~18°C, step: 0,5°C
12°C
1.5.2
[3-06]
R/W
18~30°C, step: 0,5°C
30°C
1.5.3
[3-09]
R/W
15~25°C, step: 0,5°C
15°C (*3)
1.5.4
[3-08]
R/W
25~35°C, step: 0,5°C
35°C (*3)
Room
1.6
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
1.7
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
Main zone
2.4
0: Fixed
1: WD heating, fixed cooling (*3)
2: Weather dependent
└─
Heating WD curve
2.5
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
2.5
[1-01]
R/W
10~25°C, step: 1°C
15°C
2.5
[1-02]
R/W
[9-01]~[9-00], step: 1°C
35°C
2.5
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
└─
Cooling WD curve
2.6
[1-06]
R/W
10~25°C, step: 1°C
20°C (*3)
2.6
[1-07]
R/W
25~43°C, step: 1°C
35°C (*3)
2.6
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C (*3)
2.6
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
18°C (*3)
Main zone
2.7
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
└─
Setpoint range
2.8.1
[9-01]
R/W
15~37°C, step: 1°C
25°C
2.8.2
[9-00]
R/W
[2-0C]=2:
37~60, step: 1°C
55°C
[2-0C]
≠
2:
37~55, step: 1°C
55°C
2.8.3
[9-03]
R/W
5~18°C, step: 1°C
8°C (*3)
2.8.4
[9-02]
R/W
18~22°C, step: 1°C
22°C (*3)
Main zone
2.9
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
2.A
[C-05]
R/W
0: -
1: 1 contact
2: 2 contacts
└─
Delta T
2.B.1
[1-0B]
R/W
3~10°C, step: 1°C
5°C
2.B.2
[1-0D]
R/W
3~10°C, step: 1°C
5°C (*3)
└─
Modulation
2.C.1
[8-05]
R/W
0: No
1: Yes
2.C.2
[8-06]
R/W
0~10°C, step: 1°C
5°C
└─
Shut off valve
2.D.1
[F-0B]
R/W
0: No
1: Yes
2.D.2
[F-0C]
R/W
0: No
1: Yes (*3)
Additional zone
3.4
0: Fixed
1: WD heating, fixed cooling (*3)
2: Weather dependent
└─
Heating WD curve
3.5
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
3.5
[0-01]
R/W
[9-05]~[9-06]°C, step: 1°C
50°C
3.5
[0-02]
R/W
10~25°C, step: 1°C
15°C
3.5
[0-03]
R/W
-40~5°C, step: 1°C
-10°C
└─
Cooling WD curve
3.6
[0-04]
R/W
[9-07]~[9-08]°C, step: 1°C
8°C (*3)
3.6
[0-05]
R/W
[9-07]~[9-08]°C, step: 1°C
12°C (*3)
3.6
[0-06]
R/W
25~43°C, step: 1°C
35°C (*3)
3.6
[0-07]
R/W
10~25°C, step: 1°C
20°C (*3)
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
During cooling
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
Thermostat type
Delta T heating
Modulation
Max modulation
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
Setpoint mode
Cooling minimum
Cooling maximum
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
Cooling minimum
Cooling maximum
Delta T cooling
Installer setting at variance with
default value
Emitter type
Heating minimum
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Activation
Room setpoint
Heating minimum
Heating maximum
Field settings table
During thermo
Low ambient temp. for LWT add zone heating WD curve.
Heating maximum
Setpoint mode
Room sensor offset
Room sensor offset
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Control
4P556077-1A - 2021.02
(#) Setting is not applicable for this unit.
(*1) *6V_(*2) *9W_
(*3) + EKHVCONV2_
(*4) EAVZ16S18*_(*5) EAVZ16S23*