4.3 Errors of Welbee Inverter series welding power source
4-6
4.3.2 How to reset an error indication
If an error code is displayed on the front panel of the Welbee Inverter Series welding power source
connected to the robot, the error code display cannot be reset with the "f12 <Failure Reset>” key
on the teach pendent or "External reset" signal from the basic input signals.
The error codes displayed on the front panel are released automatically when any of the
operations described below are performed. However, the displays of some error codes are not
released even with the following operations.
When pre-flow has started during automatic operation
When pre-flow has started during a check operation in which check welding is effective
When the ICH command or RTC command has been executed with welding ON automatic
operation
When inching is performed using f10 <Inching> on the teach pendant
*
When retracting is performed using f11 <Retract> on the teach pendant
*
When gas check is performed using f12 <Gas> on the teach pendant
When inching has been performed using the “inching ON/OFF” dedicated arc input signal
*
When retract has been performed using the “retract ON/OFF” dedicated arc input signal
*
When gas output has been performed using the “gas ON/OFF” dedicated arc input signal
*
This includes cases where the inching or retract speed is either high or low.
The method for clearing error displays on the “Table 4.3.1
Error code list of Welbee Inverter
series welding power source” are as shown below.
Table 4.3.2 Error display release methods
Release
method
Description
(1)
When any of the above operations is performed, the error display is
released automatically.
(2)
When the cause of the error is eliminated, the error display is released
automatically.
(3)
If the cause of the error had been eliminated when any of the above
operations was performed, the error display is released automatically.
However, since these are errors which originate in the hardware, turn the
welding power source off, and take the appropriate action described in
the operating manual of the welding power source.
(4)
The welding power source must be turned off and then turned back on in
order to release the error display.