4.3 Errors of Welbee Inverter series welding power source
4-4
4.3 Errors of Welbee Inverter series welding power source
This section describes the errors detected by the Welbee Inverter series welding power source.
4.3.1 Error code list
When using a Welbee Inverter series welding power source to connect to a robot, refer to table
Table 4.3.1 that shows the error codes in the front panel and on the teach pendant of the robot.
Table 4.3.1
Error code list of Welbee Inverter series welding power source
Digital meter
Left
Right
Contents of error
Error code of
supporting
robots
*4
Error
display
release
method
*3
E-
41
Panel communication error
A5023
(3)
E- 100
E- 110
Control power supply error
A5039
(3)
E-
150
Input over voltage
A5023
(3)
E-
160
Shortage of input voltage
A5023
(3)
E-
200
Primary current detection error
A5040
(3)
E-
210
Error in the arc voltage detection
A5030
(1)
E- 215
Error in the arc voltage detection
(RS Control)
A5097 (1)
E-
220
Primary side main circuit error
A5023
(3)
E-
230
Primary driver error
A5023
(3)
E- 240
Secondary current detection
error
A5040 (3)
E-
250
Secondary side main circuit error
A5023
(3)
E- 260
Error in the output voltage
detection circuit
A5039 (3)
E- 300
E- 301
E- 302
E- 303
Thermal overload
A5026
(3)
E- 310
E- 311
E- 312
Cooling fan error
A5023
(3)
E-
500
Lack of water pressure
For
DM/DM(S-2)/DR
/DP/DPR
A5023
For DL/DL(S-2)
A5036
(2)
E- 615
Memory
backup
error
-
(1)
E- 700
Secondary side output over
current error
A5025 (1)
E-
710
Lack of phase error
A5028
(3)
E-
800
E-
801
Encoder in the wire feeder error
A5032
(1)
E- 810
Thermal overload in the governor
circuit
A5042 (1)
Содержание OTC Almega AX Series