3.11 Welding conditions of WB-P350L/P400L/P500L
3-47
Table 3.11.6
Setting manner for each function
Function name
Function
type
Function
number
Function
Initial
value
WIF-Digital function
ON/OFF
A
1
It switches ON/OFF for the
function in this table.
ON
:
Available
OFF
:
Not available
OFF
Penetration
adjustment function
A
2
It switches ON/OFF for the
penetration adjustment function
of the welding power source.
ON
:
Available
OFF
:
Not available
OFF
Process in the fan
failure / Process in
the shortage of input
voltage
F
19
It designates the process on the
robot side when the welding
power source detects the fan
alarm or the shortage alarm of
input voltage.
ON
:
Indicates the error by
“Alarm”.
OFF
:
Not detecting the error.
OFF
Arc voltage direct
detection
F
38
Set this function ON when
connecting the voltage detection
cable for directly detecting the
arc voltage (
-
) to the welding
power source.
ON
:
Available
OFF
:
Not available
OFF
Torch
―
―
It selects the torch cooling
maner.
Press the Torch key on the front
panel. By pressing this key, LED
indicated as “Water cooled” on
the Torch key puts the light on
and off.
“Water cooled” LED ON
:
Using the water-cooled torch.
“Water cooled” LED OFF
:
Using the air-cooled torch.
OFF