1.2 Main specifications
1-3
Table 1.2.2
Connectable welding power sources
Configuration on the
robot controller
Connectable welding power sources
W.P.S.
Area
Welbee Inverter M350L (specifications for Japan)
Welbee Inverter M350L (specifications for CCC)
Japan
Welbee Inverter M350L (specifications for Asia)
Welbee Inverter M400L (specifications for Europe)
DL *1
Welbee Inverter M350L (specifications for U.S.)
U.S.
Welbee Inverter M350 (specifications for Japan)
Welbee Inverter M350 (specifications for CCC)
Welbee Inverter M350 (specifications for Asia)
Welbee Inverter M350 (specifications for U.S.)
DR *2
Japan
Welbee Inverter M400 (specifications for Europe)
Welbee Inverter M500 (specifications for Japan)
Welbee Inverter M500 (specifications for Asia)
Japan
Welbee Inverter M500 (specifications for CCC)
Welbee Inverter M500 (specifications for Europe)
DM *3
Welbee Inverter M500 (specifications for U.S.)
U.S.
Welbee Inverter P350/P350L (specifications for Japan)
Japan
Welbee Inverter P400 / P400L (specifications for CCC)
Europe
Welbee Inverter P400 / P400L (specifications for Asia)
Japan
Welbee Inverter P400 / P400L (specifications for Europe)
Europe
DP *4
Welbee Inverter P400 / P400L (specifications for U.S.)
U.S.
Welbee Inverter P350L/P500L (specifications for Japan)
Welbee Inverter P400L / P500L
(
specifications for CCC
)
Japan
Welbee Inverter P400L / P500L
(
specifications for Asia
)
DPR *5
Welbee Inverter P400L / P500L(specifications for Europe)
Welbee Inverter P400L / P500L(specifications for U.S.)
U.S.
Welbee Inverter W350
(
specifications for Japan
)
Welbee Inverter W400
(
specifications for CCC
)
Japan
Welbee Inverter W400
(
specifications for Asia
)
DW *6
Welbee Inverter W400 (specifications for Europe)
Europe
Welbee Inverter W400 (specifications for U.S.)
U.S.
Welbee Inverter A350P / A500P
(
specifications for Japan
)
Welbee Inverter A350P
(
specifications for CCC
)
Japan
Welbee Inverter A350P
(
specifications for Asia
)
DA *6
Welbee Inverter A350P (specifications for U.S.)
Welbee Inverter A350P (specifications for Europe)
Europe
*1 You can also use when set to DL or DL (S-2).
*2 Only when replacing an existing DM or DM(S-2) with the Welbee Inverter series, continue
using DM or DM(S-2)
*3 You can also use when set to DM or DM(S-2).
*4 Apply the welding characteristic data for a rated current 350A when WB-P350/P350L is in
connection.
*5 Continue using DP as is only when the existing DP-500 is replaced with WB-P500L. Also,
when using WB-P500L, a rated current 500A for WB-P500L is available at the maximum
even if it is registered as DPR in the robot controller.
Also, for rated current, you can set up to the rated current of the welding power source.
*6 For rated current, you can set up to the rated current of the connected welding power
source.
POINT
Welbee Inverter series welding power sources connected using the interface are
handled by the AXC controller as the D series welding power sources shown in
"Configuration on the robot controller" in Table 1.2.2 for operations and teaching.
If you replace an existing D series welding power source connected to the AXC controller with a
Welbee Inverter series welding power source as shown in Table 1.2.3, you can continue to use
the existing programs and welding condition file (however, you need to adjust the welding
conditions).
To replace using Welding Interface (AXWF-10
**
), you need to re-teach the arc start/end functions
(AS/AE functions) (delete and re-teach the AS/AE functions), and re-create the welding condition
file.
Содержание OTC Almega AX Series
Страница 10: ......
Страница 69: ...1 4 Welding mode lists 1 59...
Страница 109: ...2 2 Electrical connection diagram 2 10 Robot controller Figure 2 2 5 Electrical connection diagram of AXC...