3.13 Welding conditions of WB-A350P/A500P
3-61
Table 3.13.5 Setting manner for each function
Function name
Function
type
Function
number
Function
Initial
value
WIF-Digital function
ON/OFF
A
1
It switches ON/OFF for the
function in this table.
ON
:
Available
OFF
:
Not available
OFF
Process in the fan
failure / Process in
the shortage of input
voltage
F
19
It designates the process on the
robot side when the welding
power source detects the fan
alarm or the shortage alarm of
input voltage.
ON
:
Indicates the error by
“Alarm”.
OFF
:
Not detecting the error.
OFF
Arc outage detect
time (Arc End)
A
5
It checks arc outage at arc end.
If set to 0, arc outage is not
checked.
*In order to reflect the setting, the
welding power supply must be
turned off and then turned back
on again.
Unit : 0.1sec
5