![Dahua NVS0104HDC Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/dahua/nvs0104hdc/nvs0104hdc_user-manual_4170402055.webp)
Dahua Network Video Server
User’s Manual
49
Parameter
Function
Receiver
Input receiver email address here. Max three addresses.
It supports SSL, TLS email box.
Interval
The send interval ranges from 0 to 3600 seconds. 0 means
there is no interval.
Please note system will not send out the email immediately
when the alarm occurs. When the alarm, motion detection or
the abnormity event activates the email, system sends out the
email according to the interval you specified here. This
function is very useful when there are too many emails
activated by the abnormity events, which may result in heavy
load for the email server.
Health mail
enable
Please check the box here to enable this function.
Update period
(interval)
This function allows the system to send out the test email to
check the connection is OK or not.
Please check the box to enable this function and then set the
corresponding interval.
System can send out the email regularly as you set here.
Email test
The system will automatically sent out an email once to test
the connection is OK or not .Before the email test, please save
the email setup information.
4.4.2.9 FTP
You need to download or buy FTP service tool (such as Ser-U FTP SERVER) to establish
FTP service.
Please install Ser-U FTP SERVER first. From
“start” -> “program” -> Serv-U FTP Server
-> Serv-U Administrator. Now you can set user password and FTP folder. Please note you
need to grant write right to FTP upload user.
From main window->Setup->Network->FTP, the FTP interface is shown as in Figure 4-51.