Please read the followings before connecting.
1.
Alarm input
a. Please make sure alarm input mode is grounding alarm input.
b. Grounding signal is needed for alarm input.
c.
Alarm input needs the low level voltage signal.
d. Alarm input mode can be either NC (normal Open) or NO (Normal Close)
e. When you are connecting two NVSs or you are connecting one NVS and one other
device, please use a relay to separate them,
2.
Alarm output
The alarm output port should not be connected to high power load directly (It shall be less
than 1A) to avoid high current which may result in relay damage. Please use the co
contactor to realize the connection between the alarm output port and the load.
3.
How to connect PTZ decoder
a. Ensure the decoder has the same grounding with NVS; otherwise you may not
control the PTZ. Shielded twisted wire is recommended and the shielded layer is used
to connect to the grounding.
b. Avoid high voltage. Ensure proper wiring and some thunder protection measures.
c.
For too long s
ignal wires, 120Ω should be parallel connected between A, B lines on
the far end to reduce reflection and guarantee the signal quality.
d.
“485 A, B” of NVS cannot parallel connect with “485 port” of other device.
e. The voltage between of A, B lines of the decoder should be less than 5V.
4.
Please make sure the front-end device has soundly earthed.
Improper grounding may result in chip damage.
3.6.1 Alarm Input and Output Details
Figure 3-3
A1-A4
ALARM 1 to ALARM 4. The alarm becomes active in low voltage.
1-NO C, 2-NO C
There are two groups of normal open activation output (on/off button)
G
Ground cable.
3.6.2 Alarm Input Port
Please refer to the following sheet for more information.