![Dahua NVS0104HDC Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/dahua/nvs0104hdc/nvs0104hdc_user-manual_4170402012.webp)
Dahua Network Video Server
User’s Manual
6
SN
Icon
Name
Function
types; NO (normal open)/NC (normal
close).
When your alarm input device is using
external power, please make sure the
device and the NVS have the same
ground.
G
GND
Alarm input ground.
4
NO1
~
NO2
Alarm output port 1
~
2
2 groups of alarm output ports. (Group
1
:
port NO1
~
C1,Group 2:port NO2
~
C2).Output alarm signal to the alarm
device. Please make sure there is
power to the external alarm device.
NO
:
Normal open alarm output port.
C
:
Alarm output public end.
G
GND
Alarm output ground.
A
、
B
RS-485 communication
port
RS485_A port. It is the cable A. You
can connect to the control devices
such as speed dome PTZ.
RS485_B.It is the cable B. You can
connect to the control devices such as
speed dome PTZ.
RX
、
TX
RS-232 communication
port
General serial port debug.
G
GND
COM ground
5
DC 12V
Power input port
12V 2A power port. DC 8V-DC 16V.
6
GND
Ground
7
ALM
Alarm indicator light
Device local alarm has been armed
:
The light is on.
Device local alarm has triggered: The
light is flashing.
Device
local
alarm
has
been
disarmed
:
The light is off.
8
NET
Network
status
indicator light
Wire network connection is OK: The
light is off.
Wire network connection is abnormal:
The light is on.
9
RESET
Reset
Press for 5 seconds to restore default
setup.
2.2
Rear Panel
T
he rear panel is shown as below. See Figure 2-2.