User’s Manual
12
Example
Installer (default passcode is 1234) turns off the relay1 output function.
Under global mode, enter 1234*14*001.
Press
Enter
.
3.5.5
PSTN Test
Description
With the correct configuration, the controller tries to send a test message to the configured
alarm receiving center after executing the PSTN manual test command. The successful test
prompt only means that the command was sent successfully, but not that the alarm receiving
center received the message.
After executing SMS or the call manual test command, the controller sends a test message or
makes a test call to the phone to check whether the 2G/4G module, or SMS and call functions of
the controller are available.
Command
PSTN manual test: Enter pa * + 15.
SMS manual test: Enter pa * + 16 + * + phone number.
Call manual test: Enter pa * + 17 + * + phone number.
Example
Installer (default passcode is 1234) manually tests PSTN.
Under global mode, enter 1234*15.
Press
Enter
.
3.5.6
Restarting Controller
Description
Restart the alarm controller.
Command
Enter pa * + 20.
Example
Admin (default passcode is 1234) restarts the controller.
Under global mode, enter 1234*20.
Press
Enter
.