User’s Manual
11
Example
Admin (default passcode is 1234) cancels all alarms.
Under global mode, enter 1234*1.
Press
Enter
.
3.5.3
Bypass and Isolate
Description
When the whole system fails to be armed due to detector faults or human activities in some zones,
users are allowed to bypass these zones by selectively removing detectors from the security system.
For example, a detector may be bypassed in order to arm the perimeter with a window open.
Bypass: If one or more zones are bypasses, they are disabled for one arming cycle. After one
arming cycle, they are automatically unbypassed.
Isolate: If one or more zones are isolated, they are disabled until they are unbypassed.
Unbypass: Manually restores a zone to normal functioning by removing a bypass condition.
Command
Unbypass: Enter pa * + 7 + * + zone number.
Bypass: Enter pa * + 8 + * + zone number.
Isolate: Enter pa * + 9 + * + zone number.
Example
Admin (default passcode is 1234) bypass zone1.
Under the global mode, enter 1234*8*001.
Press
Enter
.
3.5.4
Relay
Description
Manually turn on or off the relay output.
Command
Manually turn on the relay output: Enter pa * + 13 + * + relay number.
Manually turn off the relay output: Enter pa * + 14 + * + relay number.
The 3-digit relay number ranges from 001 to 256, and it uses 0 as placeholder in front when there are
less than 3 digits (e.g. 10 becomes 010).