User’s Manual
21
The admin user enters 10300101 under programming mode.
Press
Enter
.
3.6.3.4
Entry Delay Time
Description
A programmed delay in the system alarm response that allows an individual to enter an armed area
through the correct detector and disarm the area. If the system is not disarmed before the delay time
expires, the system will initiate an alarm response which may include sending reports to the central
station.
Command
Enter delay time
104
①
001
③
②
30
Table 3-9
Entry delay time
Number Description
1
The encoding address. The command operation means configuring entry delay time.
2
Zone.
ARC9 series: 001-256.
ARC2 series
ARC2008 series: 001-072.
ARC2016 series: 001-080.
3
Entry delay time. The entry delay time can be set between 1 to 300 seconds.
Example
The admin user configures the
entry delay time of zone 1 as 30 s.
The admin user enters 10400130 under programming mode.
Press
Enter
.