User’s Manual
10
example, bypass zone can bypass up to 16 zones at the same time.
3.5.1
Arming and Disarming
Description
Arming: When the controller and the detectors work properly, arm the zone, and then the
controller will respond to alarm signals in the zone.
Disarming: Disarm the zone when it is in the armed status.
Command
Switch system status: Enter passcode.
Disarm subsystem: Enter pa * + 2 + * + subsystem number.
Away arm subsystem: Enter pa * + 3 + * + subsystem number.
Forced away arm subsystem: Enter pa * + 4 + * + subsystem number.
Home arm subsystem: Enter pa * + 5 + * + subsystem number.
Forced home arm subsystem: Enter pa * + 6 + * + subsystem number.
Arm single zone: Enter pa * + 10 + * + zone number.
Disarm single zone: Enter pa * + 11 + * + zone number.
Switching system status means that you can switch the arming/disarming status of each active
subsystem. For example, if the current subsystem is in the armed status, enter the command and the
subsystem changes to the disarmed status.
Example
Admin (default passcode is 1234) performs away arming on subsystem1.
Under global mode, enter 1234*3*01.
Press
Enter
.
3.5.2
Cancel Alarm
Description
Cancel the alarm through the keypad when an alarm is triggered.
Command
Cancel all alarms: Enter pa * + 1.
Cancel zone alarm: Enter pa * + 1 + * + zone number.
Cancel subsystem alarm: Enter pa * + 23 + * + subsystem number.