11. PRECAUTIONS
−
The electropump should not be started an excessive
number of times in one hour. The maximum
admissible value is as follows:
Maximum number
of start per hour
Single-Phase Motors
30
Three-Phase Mot. up to 5.5 HP
20 ÷ 30
Three-Phase Mot. from 7.5 to 60 HP
5 ÷ 10
11.1 Danger of frost
When the pump remains inactive for a long time at
temperatures of less than 0°C, the pump body must be
completely emptied to prevent possible cracking of the
hydraulic components. This operation is advisable even
in the event of prolonged inactivity at normal
temperature.
Check that the leakage of liquid
does not damage persons or things,
especially in plants that use hot
water. The system must be drained
only once the fluid temperature has
reached environment temperature.
Do not close the drainage cap until the pump is to be
used again.
When restarting after long periods of inactivity it is
necessary to repeat the operations described above in
the paragraphs
“WARNINGS”
and
“STARTING UP”
.
12.
MAINTENANCE AND CLEANING
As well as being at high temperature
and high pressure, the fluid in the
system may also be in the form of
steam! DANGER OF BURNING!
It may be dangerous even to touch the pump or
parts of the system.
The electropump can only be
dismantled by competent skilled
personnel, in possession of the
qualifications required by the
legislation in force.
In any case, all repair and maintenance jobs must be
carried out only after having disconnected the pump from
the power mains. Ensure that it cannot be switched on
accidentally.
If possible, keep to a maintenance schedule: expensive
repairs or machine down times can be avoided with a
minimum expense. During maintenance schedule
discharge the condensate, if necessary present into the
motor, through the hole, removing the exhaust port plug no
(electropumps with IP55 Degree of motor protection only).
If the liquid has to be drained out
maintenance, ensure that the liquid
coming out cannot harm persons or
things, especially in using hot water.
The legal requirements on the disposal of any harmful
fluids must also be complied with.
−
In normal operation, the pump does not require any
kind of maintenance. However, from time to time it is
advisable to check the plate data, which will enable
you to have advance warning of any faults or wear.
−
After any operation involving the removal of the
motor head from the pump body, it is advisable to
change the O-ring between the pump body and the
support.
12.1 Modifications and spare parts
Any modification not authorized beforehand relieves
the manufacturer of all responsibility.
All the spare
parts used in repairs must be original ones and the
accessories must be approved by the manufacturer so as
to be able to guarantee maximum safety of persons and
operators, and of the machines and systems in which they
may be fitted.
13. TROUBLESHOOTING.
Fault
Check (possible cause)
Remedy
−
Check the protection fuses.
If they are burnt-out, change them.
−
Check the electric connections.
The motor does not start and makes
no noise.
−
Check that the motor is live.
If the fault is repeated immediately
this means that the motor is short
circuiting.
−
The impeller is worn or blocked.
Change the impeller or remove the
obstruction.
The pump supplies insufficient flow.
−
Check that the direction of
rotation on three-phase versions
is correct.
Invert the connection of two supply
wires.
Содержание CP
Страница 2: ...P 7 5 kW P 7 5 kW...
Страница 43: ...37 5 5 1 5 2 1 2 1 2 5 3 6 6 1 CEI 64 2 6 2 6 3 3 DIN 4181 3 5 1 2 4 3 1 2 3 4 5 7 7 1 7 2 A 66 LpA 85 A 7 3...
Страница 44: ...38 8 40 C B IP55 C 9 67 B 66 D 10 E F 5 G...
Страница 45: ...39 11 30 5 5 20 30 7 5 60 5 10 11 1 0 C 12 IP55 12 1 13...
Страница 46: ...40...
Страница 78: ......
Страница 79: ......