ENGLISH
11
Pag.
1.
GENERAL
11
2.
APPLICATIONS
11
3. PUMPED FLUIDS
11
4. TECHNICAL DATA
11
4.1 Electrical data
11
4.2 Operating conditions
11
5.
MANAGEMENT
12
5.1 Storage
12
5.2 Transports
12
5.3 Weights
12
6.
WARNINGS
12
6.1 Safety
12
6.2 Checking motor shaft rotation
12
6.3 New systems
12
7.
PROTECTIONS
12
7.1 Moving parts
12
7.2 Noise level
12
7.3 Hot and cold parts
12
8.
INSTALLATION
13
9. ELECTRICAL CONNECTION
13
10. STARTING UP
13
11. PRECAUTIONS
14
11.1 Danger of frost
14
12. MAINTENANCE AND CLEANING
14
12.1 Modifications and spare parts
14
12.2 Blanking flanges
14
13. TROUBLESHOOTING
14
Table A
76
Airborne noise produced by the pumps
with standard motor
Table B
76
Star-delta switch-over times
Table C
77
THREE-PHASE motor connection
Fig. 8 Installation dimensions
83
Fig.9 Cleaning the check valve
compartment
84
1. GENERAL
Read this documentation carefully
before installation. It contains
fundamental instructions to be
followed during installation,
operation and maintenance.
Installation and functioning must comply with the safety
regulations in force in the country in which the product is
installed.
The entire operation must be carried out in a
workmanlike manner, exclusively by skilled personnel,
in possession of the technical qualifications indicated by
the standards in force. Failure to comply with the safety
regulations not only causes risk to personal safety and
damage to the equipment, but invalidates every right to
assistance under guarantee.
The appliance is not intendend for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsable for their safety.
Children should
be supervised to ensure that they do not play with the
appliance.
2. APPLICATIONS
Pumps for circulating hot and cold water, with apertures
in line for installations in series with plant pipes.
Suitable for civil and industrial heating, conditioning and
chilling plants and for domestic hot water systems.
3. PUMPED FLUIDS
The machine has been designed and built for pumping
water, free from explosive substances and solid
particles or fibres, with a density of 1000 kg/m³ and a
kinematic viscosity of 1 mm²/s, and chemically non-
aggressive liquids. Use with other fluids is allowed only
with the manufacturer’s authorization.
4. TECHNICAL DATA
4.1 Electrical data
- Supply voltage:
3 x 230-400V 50/60 Hz
up to 2.2 KW inclusive
3 x 400V
50/60 Hz
over 2.2 KW
- Absorbed power:
see electric data plate
- Degree of motor protection:
see plate on package
- Thermal class:
F
4.2 Operating conditions
- Delivery:
- Head up - Hmax (m):
see electric data plate
pag. 78
- Liquid temperature range:
-10
÷ 140
°C
- Environment temperature:
0
÷
40°C
- Storage temperature:
-10
÷
40°C
- Max. working pressure:
16 bar (1600 kPa)
- Relative humidity of the air:
Max. 95%
- Standard apertures:
DN 65÷150 - PN 16
Содержание CM-G
Страница 2: ...P 7 5 kW P 7 5 kW...
Страница 43: ...38 C 8 9 77 B 76 D 10 E F 5 G 11 30 5 5 20 30 7 5 60 5 10 11 1 0 C...
Страница 44: ...39 12 IP55 12 1 12 2 4 Fig 4 13...
Страница 45: ...40...
Страница 78: ...73 C 8 9 3 D 3 10 E 3 F 5 G 11 1 30 3 5 5 HP 20 30 3 7 5 60 HP 5 10 11 1 0 C...
Страница 79: ...74 12 12 1 12 2 4 Fig 4 13 The pump supplies insufficient flow 3...
Страница 80: ...75...
Страница 90: ...85...
Страница 91: ...86...