ENGLISH
19
1. General
1.1 Applications
2. Pumped
fluids
3. Technical data
3.1 Electrical data
3.2 Operating conditions
3.3 Description of model properties
4. Functions
4.1 Control panel
4.2 Control panel functions
4.3 Regulating the Start pressure
4.4 Stopping the pump
5. Installation and connection
5.1 Pump installation
5.2 Electrical connections
5.3 Starting
6. Maintenance
6.1 Starting the pump after a long
period of inactivity
6.2 Modifications and spare parts
6.3 Service kit
7. Troubleshooting
8. ACTIVE SYSTEM kit assembly
8.1 Pumps suitable for fitting the
ACTIVE SYSTEM kit
8.2 Instructions for assembly of the
ACTIVE SYSTEM kit
Fig. 14 Changing the electronic card
Fig. 15 Active System kit assembly
Fig. 16 Electronic card connections
Fig. 17 Load loss diagram
Page
19
19
19
19
19
19
20
20
20
21
21
22
22
22
23
23
24
24
24
24
25
26
26
26
27
109
110
111
1. GENERAL
ACTIVE
is a compact pressure boosting system
composed of a pump, a motor and a built-in control
unit, which can also be installed outside.
The pump, with the Active system, starts automatically
when there is water consumption and stops when the
request for water ends.
The system is equipped with:
−
an easy-to-use control panel,
−
a built-in tank with diaphragm which reduces the
number of starts and stops in the event of leaks
from the pipe,
−
protection against dry running
.
1.1 Applications
Active
is used particularly for increasing pressure in
storage tanks and for supplying water from wells:
−
in houses,
−
in holiday homes,
−
in farms,
−
in greenhouses and gardens
.
The pump can be used for pumping rainwater and
drinking water.
2. PUMPED FLUIDS
The machine has been designed and built for pumping
water, free from explosive substances and solid
particles or fibres, with a density of 1000 kg/m³ and a
kinematic viscosity of 1 mm²/s, and chemically non-
aggressive liquids.
3. TECHNICAL DATA
3.1 Electrical data
- Supply voltage:
1x220-240V
-10+6%
50-60Hz
- Max. current: 6.5
A
- Degree of protection:
IP 55 Active System
IP 44 Motor
- Insulation class: F
- Power cable:
1.5 mt H05 RN-F
with/without plug
3.2 Operating conditions
- Range of operation:
- Head up – Hmax (m):
0.3
÷
8.4 m³/h
page 112
- Liquid temperature:
0
÷
35°C domestic use
(EN 60335-2-41)
- Environment temperature:
0
÷
40°C
-
Storage temperature:
-10
÷
40°C
- Maximum working pressure:
8 bar (800 Kpa)
- Relative humidity in air: Max.
95%
- Starting pressure:
1.5
÷
2.5 bar (settable)
- Connections:
1” GAS / NPT
Read this documentation
Carefully before
Installation.
Installation, electrical connection and commissioning
must be carried out by skilled personnel in
compliance with the general and local safety
regulations in force in the country of installation of
the product. Failure to comply with these instructions
not only causes risk to personal safety and damage
to the equipment, but invalidates every right to
assistance under guarantee.
- Noise level:
Directive EC 89/392/EEC