3.3  Description of model properties. 

 
 

Pump model 

Active J 

Active JI 

Active JC 

Active E 

Active EI 

Active EC 

Characteristics 

Self-priming centrifugal 

centrifugal  

self-priming 

centrifugal 

Applications 

with water from an artesian well or 

underground tank

 

pressurization

 for 

domestic use  

with water from 

an artesian well 

or underground 

tank 

pressurization

 for 

domestic use 

Limitations 

suction up to 8 metres

 

water without 

dissolved gases 

suction up to 8 

metres 

water without 

dissolved gases

Installation 

conditions  

 

with foot valve 

 

below head 

with foot valve 

below head 

Particular 

characteristics 

 

suitable 

for 

pumping 

water 

containing 

air 

stainless 

suitable for 

pumping 

water 

containing 

air 

hydraulic, 

technopolymer 

suitable for 

pumping water 

containing air 

silent running 

silent running 

and stainless , 

suitable for 

pumping water 

containing air 

hydraulic, 

technopolymer, 

silent running 

Advantages 

with respect 

to traditional 

systems 

 

reduced bulk – greater hygiene – pressure stability– adjustable starting pressure  

pump blockage in the event of water lack – self-starting in the event of alarm 

limitation of the number of starts – protection against excess temperature of hydraulic parts  

built-in no-return valve and pressure gauge – possibility of remote alarm signal. 

 
 

4. FUNCTIONS 

 

 

4.1  Control panel  

 

ACTIVE 

is managed by a control panel which offers: 

− 

the possibility of checking the pump operating status by means of warning lights:  

     Green ON  -  Red ALARM (Fig.1) 

− 

the possibility of setting the Start pressure (Fig.2) 

 
 
 

Control panel– Fig. 1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

green         red 

Содержание ACTIVE J 62

Страница 1: ...CTIONS FOR INSTALLATION AND MAINTENANCE INSTALLATIONSANWEISUNG UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERH LLS...

Страница 2: ...N VERPANEL KONTROL PANELI PANOU DE CONTROL XB w A R TAPPO DI CARICO BOUCHON DE REMPLISSAGE FILLING CAP F LLSCHRAUBE VULDOP TAP N DE CARGA P FYLLNINGSPLUGG DOLDURMA TIPASI CAPAC DE NC RCARE IlK A Bio T...

Страница 3: ...0 6 ACTIVE E 30 30 6 ACTIVE EI 30 30 6 ACTIVE EC 30 30 6 ACTIVE E 40 30 6 ACTIVE EI 40 30 6 ACTIVE E 30 50 6 ACTIVE EI 30 50 6 ACTIVE EC 30 50 6 ACTIVE E 40 50 6 ACTIVE EI 40 50 6 ACTIVE EC 40 50 6 AC...

Страница 4: ...ingen DECLARACI N DE CONFORMIDAD La empresa DAB PUMPS s p a Via Marco Polo 14 Mestrino PD ITALY bajo su propia y exclusiva responsabilidad declara que los productos Active Active System rese ados ante...

Страница 5: ...against dry running 1 1 Applications Active is used particularly for increasing pressure in storage tanks and for supplying water from wells in houses in holiday homes in farms in greenhouses and gar...

Страница 6: ...or pumping water containing air hydraulic technopolymer suitable for pumping water containing air silent running silent running and stainless suitable for pumping water containing air hydraulic techno...

Страница 7: ...cess temperature of hydraulic parts There is the possibility of remote signalling of the alarm signal in fact on the electronic card Active has two male faston outlets 4 7 mm to allow the connection s...

Страница 8: ...ke opening horizontal and the delivery opening vertical The pump must be installed exclusively in horizontal position Fig 3 To avoid transmitting vibrations to the system after delivery it is recommen...

Страница 9: ...ct operating voltage and frequency are indicated on the pump data plate Never make any connection on the terminal card if the electric power supply has not been deactivated for at least 5 minutes 5 3...

Страница 10: ...lectronic components of the pump if the power has not been turned off for at least 5 minutes If there is the risk of damage caused by frost drain the pump through the drainage cap Fig 12 The pump must...

Страница 11: ...the voltage for a few seconds The existing pipe has a leak or is faulty Repair the pipe The pump does not stop The check valve is blocked or missing Clean the valve dismantling the system Dry running...

Страница 12: ...50 M Jet 102 M Jetinox 102 M Jetcom 102 M Euro 30 50 M Euroinox 30 50 M Eurocom 40 50 M Jet 112 M Jetinox 112 M Euro 40 50 M Euroinox 40 50 M Jet 132 M Jetinox 132 M Jetcom 132 M Euro 50 50 M Euroinox...

Страница 13: ...y specialised qualified personnel Reduce the system pressure it is recommended to close the valve of the system located for this purpose on delivery near the pump Disconnect the electric connectors of...

Страница 14: ...n n montaj ACTIVE SYSTEM Montajul Kit ului Active System ACTIVE SYSTEM A J yZK Fig 15 Abb 15 Afb 15 15 Res 15 15 15 Z e 1 2 I Avvitare fino alla battuta F Visser fond GB Screw fully down D Bis zum An...

Страница 15: ...EXION NORMALE GB NORMAL CONNECTION D NORMALER ANSCHLUSS NL NORMALE VERBINDING E CONEXI N NORMAL S NORMAL ANSLUTNING GR T NORMAL BA LANTI RU RM CONEXIUNE NORMAL n XBk Be G I CONNESSIONE ACTIVE F CONNEX...

Страница 16: ...agram ladingverlies Diagrama p rdidas de carga Diagram ver tryckf rluster Y k kayb diyagram Diagrama pierderi de nc rc tur R A AXwt i iUK aZ Fig 17 Abb 17 Afb 17 17 Res 17 17 17 Z e ACTIVE Hydraulic L...

Страница 17: ...E JC 132 48 3 48 3 ACTIVE E 25 30 25 306 34 5 35 9 ACTIVE E 30 30 30 306 46 48 2 ACTIVE E 40 30 40 306 57 58 8 ACTIVE E 30 50 30 506 42 5 38 8 ACTIVE E 40 50 40 506 57 5 54 ACTIVE E 50 50 50 506 72 66...

Страница 18: ...113...

Страница 19: ...114...

Страница 20: ...05 06 cod 0013 600 17...

Отзывы: