117
Chapter 6
Troubleshooting
6.1
System buzzer
The system buzzer features are listed below:
1.
The system buzzer alarms 1 second when system boots up successfully.
2.
The system buzzer alarms continuously when there is error occurred. The alarm will
be stopped after error resolved or be muted.
3.
The alarm will be muted automatically when the error is resolved. E.g., when RAID 5
is degraded and alarm rings immediately, user changes / adds one physical disk for
rebuilding. When the rebuilding is done, the alarm will be muted automatically.
6.2
Event notifications
PD events
Level Type
Description
INFO
PD inserted
Disk <slot> is inserted into system
WARNING PD removed
Disk <slot> is removed from system
ERROR
HDD read error
Disk <slot> read block error
ERROR
HDD write error
Disk <slot> write block error
ERROR
HDD error
Disk <slot> is disabled
ERROR
HDD IO timeout
Disk <slot> gets no response
INFO
PD upgrade started
PD [<string>] starts upgrading firmware process.
INFO
PD upgrade
finished
PD [<string>] finished upgrading firmware process.
WARNING PD upgrade failed
PD [<string>] upgrade firmware failed.
HW events
Level Type
Description
WARNING ECC single
Single-bit ECC error is detected at <address>
ERROR
ECC multiple
Multi-bit ECC error is detected at <address>
INFO
ECC dimm
ECC memory is installed
INFO
ECC none
Non-ECC memory is installed
INFO
SCSI bus reset
Received SCSI Bus Reset event at the SCSI Bus <number>
ERROR
SCSI host error
SCSI Host allocation failed
ERROR
SATA enable device
fail
Failed to enable the SATA pci device
ERROR
SATA EDMA mem
fail
Failed to allocate memory for SATA EDMA
ERROR
SATA remap mem
fail
Failed to remap SATA memory io spcae