DIS-200G Series Gigabit Ethernet Switch CLI Reference Guide
255
mode: Represent the mode of ASV 2.0. And the mode can be standard or
surveillance.
DDM
Log Description
Severity
Event description: when the any of SFP parameters exceeds from the warning
threshold.
Log Message: Optical transceiver <interface-id> <component> <high-low> warning
threshold exceeded
Parameters description:
interface-id: port interface ID.
component: DDM threshold type. It can be one of the following types:
temperature
supply voltage
bias current
TX power
RX power
high-low: High or low threshold.
Warning
Event description: when the any of SFP parameters exceeds from the alarm threshold.
Log Message: Optical transceiver <interface-id> <component> <high-low> alarm
threshold exceeded
Parameters description:
interface-id: port interface ID.
component: DDM threshold type. It can be one of the following types:
temperature
supply voltage
bias current
TX power
RX power
high-low: High or low threshold.
Warning
Event description: when the any of SFP parameters recovers from the warning
threshold.
Log Message: Optical transceiver <interface-id> <component> back to normal
Parameters description:
interface-id: port interface ID.
component: DDM threshold type. It can be one of the following types:
temperature
supply voltage
bias current
TX power
RX power
Warning