DIS-200G Series Gigabit Ethernet Switch CLI Reference Guide
102
This example shows how to configure the time interval to 20 seconds.
Switch# configure terminal
Switch(config)# loopback-detection interval 20
Switch(config)#
21-4
loopback-detection recover-time
This command is used to configure the recover timer interval. Use the
no
form of this command to revert to the
default setting.
loopback-detection recover-time
SECONDS
no loopback-detection recover-time
Parameters
recover-time
SECONDS
0 or 60-1000000. 0 will keep a port disabled until next device
restart.
Default
By default, this value is 60 seconds.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 15.
Usage Guideline
Use this command to configure the recover time when the loop port will enable.
Example
This example shows how to configure the time interval to 100 seconds.
Switch# configure terminal
Switch(config)# loopback-detection recover-time 100
Switch(config)#
21-5
show loopback-detection
This command is used to display the current loopback detection control settings.
show loopback-detection [interface
INTERFACE-ID
[, | -]]
Parameters
interface
INTERFACE-ID
(Optional) Specifies the interface’s ID to be displayed.