DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
710
DGS-3000-26TC:admin#download cfg_fromRCP username rcp_user 172.18.212.106
src_file /home/DGS-3000.cfg
Command: download cfg_fromRCP username rcp_user 172.18.212.106 src_file
/home/DGS-3000.cfg
Connecting to server................... Done.
Download configuration................. Done.
DGS-3000-26TC:admin#
upload cfg_toRCP
71-4
Description
This command is used to upload a configuration file from the device to an RCP server. If the
remote filename is not specified, the default file name will be modelname-image-id.
Format
upload cfg_toRCP [{username <username 15>} {<ipaddr>} dest_file <path_filename 64> |
rcp: <string {user@}ipaddr/path_filename>] {src_file <pathname 64>} {[include | exclude |
begin] <filter_string 80> {<filter_string 80> {<filter_string 80>}} {[include | exclude | begin ]
<filter_string 80> {<filter_string 80> {<filter_string 80>} } {[include | exclude | begin ]
<filter_string 80> {<filter_string 80> {<filter_string 80>}}}}}
Parameters
username
- (Optional) Specify the remote user name on the RCP server.
<username 15>
- Enter the remote user name on the RCP server.
<ipaddr>
- (Optional) Enter the IP address of the RCP server.
dest_file
- Specify the path name on the RCP server.
<path_filename 64>
- Enter the path name on the RCP server or local RCP client.
rcp:
- Specify the path and the login credentials of the configuration file located on the RCP
server that will be used for the upload.
<string {user@}ipaddr/path_filename>
- Enter the path and the login credentials of the
firmware file located on the RCP server that will be used for the upload. No spaces are
allowed. For example, [email protected]/home/user_name/firmware.had.
src_file
- (Optional) Specify the path name of the source file.
<pathname 64>
- Enter the path name of the source file. Note that if no path name is Specify,
only the current device configuration will be uploaded.
include
- (Optional) Includes lines that contain the specified filter string.
exclude
- (Optional) Excludes lines that contain the specified filter string.
begin
- (Optional) The first line that contains the specified filter string will be the first line of the
output.
<filter_string 80>
- Enter a filter string enclosed by the quotation mark symbol. Thus, the filter
string itself cannot contain the quotation mark character. The filter string is case sensitive.
<filter_string 80>
- (Optional) Enter a filter string enclosed by the quotation mark symbol.
<filter_string 80>
- (Optional) Enter a filter string enclosed by the quotation mark symbol.
include
- (Optional) Includes lines that contain the specified filter string.
exclude
- (Optional) Excludes lines that contain the specified filter string.
begin
- (Optional) The first line that contains the specified filter string will be the first line of the
output.
<filter_string 80>
- Enter a filter string enclosed by the quotation mark symbol. Thus, the filter
string itself cannot contain the quotation mark character. The filter string is case sensitive.
<filter_string 80>
- (Optional) Enter a filter string enclosed by the quotation mark symbol.
<filter_string 80>
- (Optional) Enter a filter string enclosed by the quotation mark symbol.
Содержание DGS-3000 series
Страница 1: ......