CONFIGURATION & CONNECTORS
2-8
2410-41, 2410-42 and 2410-43 FEP Maintenance & Support Guide
Revision 1.0, May 2006
2.8
SWITCHES
2.8.1
FEP Power Supply Switches
The 600-2410-43-D0, 600-2410-42-D0 and 600-2410-41-D0 DC unit has a single power switch. This
switch enables and disables power from both power entries to both power supplies. The ‘1’ position
indicates power supply ON and ‘0’ position indicates power supply OFF.
The 600-2410-43-A0, 600-2410-42-A0 and 600-2410-41-A0 AC unit has two power switches, each
switch associated with one of the power entry modules. AC power switch A enables and disables power
entry to power supply A and AC power switch B enables and disables power entry to power supply B.
9
0
CPCI-824 Gbit Ethernet 0
ACT
Indicates network activity for port 0 and will blink during
transmit and receive activity.
10
0
CPCI-824 Gbit Ethernet 0
LNK
Indicates link integrity for Ethernet port 0 and will remain on
continuously if port 0 is connected to a functional network or
Ethernet port.
11
0
CPCI-824 Gbit Ethernet 1
ACT
Indicates network activity for port 1 and will blink during
transmit and receive activity.
12
0
CPCI-824 Gbit Ethernet 1
LNK
Indicates link integrity for Ethernet port 1 and will remain on
continuously if port 1 is connected to a functional network or
Ethernet port.
13
0
CPCI-824 10/100 Ethernet
0 ACT
Indicates network activity for port 0 and will blink during
transmit and receive activity.
14
0
CPCI-824 10/100 Ethernet
0 LNK
Indicates link integrity for Ethernet port 0 and will remain on
continuously if port 0 is connected to a functional network or
Ethernet port.
15
0
CPCI-824 10/100 Ethernet
1 ACT
Indicates network activity for port 1 and will blink during
transmit and receive activity.
16
0
CPCI-824 10/100 Ethernet
1 LNK
Indicates link integrity for Ethernet port 1 and will remain on
continuously if port 1 is connected to a functional network or
Ethernet port.
17
0
CPCI-824 Hot Swap
This will illuminate when it is permissible to extract the
CPCI-824.It also lights at power-up and during reset and
when the lower handle is open.
18
0
Power Supply A
The FEP Power Supply green ‘POWER’ LED is located on
the power supply. It illuminates when the power supply is
ON. The red ‘FAULT’ LED will light while the power supply
is hot swapped, or if the power supply is faulty, or if there is
no power supplied to the power entry module.
19
0
Power Supply B
The FEP Power Supply green ‘POWER’ LED is located on
the power supply. It illuminates when the power supply is
ON. The red ‘FAULT’ LED will light while the power supply
is hotswapped or if the power supply is faulty, or if there is
no power supplied to the power entry module.