background image

19 

STEP 2 

Add User Account(s) 

Once you have set up the VPN server, select 

Continue

.   

 

Before remote users can set up a VPN tunnel to the CyberGuard SG 
appliance’s PPTP server, they must have user accounts set up.  The 
field options in the 

Add New Account

 are detailed below. 

Username 

This User Name is required for VPN authentication 
only.  The name selected is case sensitive (for example 

Jimsmith

 is not the same as 

jimsmith

). 

Windows 
Domain 

Optional.  Most Windows clients expect you to specify a 
domain name in upper case. 

Password 

Enter the password for the remote VPN user. 

Confirm 

Re-enter the password to confirm. 

 

20

 

As new VPN user accounts are added, they are displayed on the 
updated 

Account List

.   

To modify the password of an existing account, 

Select 

the account in the 

Account List

 

then enter 

New Password

 and 

Confirm

 in the 

Delete or 

Change Password for the Selected Account

 field. 

Similarly to delete an existing account, 

Select 

the account in the 

Account List

 then check 

Delete 

in the 

Delete or Change Password for 

the Selected Account

 field.   

If you request a change to a User Account and it is successful, the 

PPTP 

VPN Server Setup

 page will be displayed with the change noted.  If the 

change was unsuccessful, an error will be reported. 

STEP 3 

Configure Remote Client 

At the remote sites there is generally no need for any special client 
software.  Your CyberGuard SG appliance’s PPTP server supports the 
standard PPTP client software included with Windows.  The virtual 
private network connection is simple to configure using the standard 
Dial-Up Networking software.  PPTP is also compatible with Linux/Unix 
PPTP client software. 

These instructions will cover a Windows 2000 client.  Please refer to the 
User Manual if you have a different operating system. 

Click 

Start, Settings, Network and Dialup Connections.  

Choose 

Make New Connection

 

Choose 

Connect to a private network through the Internet.  

Click 

Next. 

Содержание SG565

Страница 1: ...9_Cert_WMIR 103G This document must not be copied or reproduced except in full without the written permission of the Manager EMC Technologies Pty Ltd The certificate on page 3 may be reproduced in ful...

Страница 2: ...t up your CyberGuard SG appliance s Internet connection settings Set up the PCs on your LAN to access the Internet Occasionally you will see a box like the following which contains important technical...

Страница 3: ...front panel LEDs flashing If these LEDs do not behave in this manner before your CyberGuard SG appliance has been attached to the network you may need to perform a factory reset Press the black Reset...

Страница 4: ...appliance s password and LAN connection settings Launch Internet Explorer or your preferred web browser and navigate to 192 168 0 1 The Web Management Console will display Select Quick Setup Wizard f...

Страница 5: ...o have automatically configure your CyberGuard SG appliance s LAN connection settings You may skip to STEP 4 Click Next 8 Note This page will only display if you previously selected Manual configurati...

Страница 6: ...up the PCs on your LAN to access the Internet If you haven t already connect your CyberGuard SG appliance s LAN port directly to your LAN hub using the straight through Ethernet cable blue Note if you...

Страница 7: ...steps for each PC on your network You are now finished 12 Alternatively to activate your CyberGuard SG appliance s DHCP server Launch Internet Explorer or your preferred web browser and navigate to th...

Страница 8: ...ive mode for keying and be established going out through the default gateway interface Proceed to CyberGuard SG to CyberGuard SG VPN IPSec Please refer to the IPSec section of the User Manual if you a...

Страница 9: ...he remote party has a static IP address enter the other CyberGuard SG appliance s public Internet IP address in The remote party s IP address If you selected The remote party has a dynamic IP address...

Страница 10: ...her the connection is Down or Running Status will display Negotiating Phase 1 then Negotiating Phase 2 as the connection is being established 18 Remote Workstation to CyberGuard SG VPN PPTP STEP 1 Ena...

Страница 11: ...for the Selected Account field Similarly to delete an existing account Select the account in the Account List then check Delete in the Delete or Change Password for the Selected Account field If you r...

Страница 12: ...anship and material except in those cases where the materials are supplied by the Purchaser under normal and proper use and service for the period of one 1 year from the date of original purchase from...

Страница 13: ...ADVISED OF THE POSSIBILITY OF SUCH DAMAGES 24 Extended Four Year Warranty If Purchaser buys Extended Warranty at time of purchase of the product or within thirty 30 days from date of original purchase...

Страница 14: ...PROPERTY RIGHTS The Software is protected by copyright laws international copyright treaties and other intellectual property laws and treaties SnapGear and its suppliers retain all ownership of and i...

Страница 15: ...TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OTHER THAN AS STATED HEREIN THE ENTIRE RISK AS TO SATISFACTORY QUALITY PERFORMANCE ACCURACY AND EFFORT IS WITH YOU ALSO THERE IS NO WARRANTY...

Страница 16: ...520055 07 SPC 1 Product Compliance Information...

Страница 17: ...SG710 990136 SG710 990183 Telephone extension cable 6ft 1 8m Ethernet cross over cable 6ft 1 8m grey 1 1 1 1 1 1 Ethernet cross over cable 6ft 1 8m red Ethernet patch cable 6ft 1 8m blue 2 1 1 1 1 1...

Страница 18: ...levant to Products SG300 was LITE300 990126 SG630 was PCI630 990071 SG635 was PCI635 990135 SG530 was SME530 990064 SG550 was SME550 990065 SG570 was SME570 990107 SG575 was SME575 990108 SG710 990136...

Страница 19: ...gar CyberGuard Corporation att denna ITE st r I verensst mmelse med de v sentliga egenskapskrav och vriga relevanta best mmelser som framg r av direktiv 1999 5 EG Undertegnede CyberGuard Corporation e...

Страница 20: ...ult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not c...

Страница 21: ...l RENs contact the local telephone company 9 The following information may be required when applying to your local telephone company for leased line facilities Service Type REN USOC Analog 0 3B RJ 11C...

Страница 22: ...2th Avenue Deerfield Beach Florida 33442 USA Phone 1 954 375 3500 Fax 1 954 375 3501 Type of Equipment Information Technology Equipment Equipment Description Part Description 990126 KIT SG300 was LITE...