CyberData Corporation
930109C
VoIP Zone Controller 4-Port Audio Out Operations Guide
Implementing the VoIP Zone Controller
Configuring the VoIP Zone Controller
14
To change the default Web access Username and Password:
1. Enter the new Username from four to 25 alphanumeric characters in the
Change Username
field. The Username is case-sensitive.
2. Enter the new Password from four to 20 alphanumeric characters in the
Change Password
field.
The Password is case-sensitive.
3. Enter the new password again in the
Re-enter New Password
field.
4. Click
Save Settings
.
2.4.5 Configure the SiP Parameters
The SIP parameters enable the VoIP Zone Controller to contact and register with the SIP server. On
the Home page, click
SIP Setup
to open the
SIP Configuration
page.
Link to the
Network Setup
web page.
Link to the
SIP Setup
web page.
Link to the
Zones Setup
web page.
Link to the
Upgrade Firmware
web page.
Link to the
Home
page.
Table 2-3. Administrator Settings Parameters (continued)
Web Page Item
Description