Installation
V.34bis Series Standalone & Rackmount Modems
17
For LAL command input from pin 18:
Set S2-3 OFF then set S2-5 ON.
Rackmount Modems
To force DSR ON:
S2-6 ON
To force CD ON:
S2-7 ON
To force CTS ON:
S2-8 ON
External Series Modems
To force DSR ON:
SW2-1
To force CD ON:
SW2-2
To force CTS ON:
SW2-3
SW2-4 is used for Dumb Mode
Power On Test
External Modems
Turn on the power to the modem by sliding the rear panel power switch to
the ON position.
If the modem passes the power-up self-test, three short beeps will be
heard. Failure is indicated by four lower-pitched tones and the LEDs will
indicate the type of failure.
After the self-test, the DTR LED begins to flash if DTE is not connected or
turns on if the DTE is connected and provides an on signal.
Rackmount Modems
With power applied to the rack, insert a module card into the rack.
If the modem passes the power-up self-test, three short beeps will be
heard. Failure is indicated by four lower-pitched tones.
Содержание V.34bis series
Страница 10: ...Introduction 6 V 34bis Series Standalone Rackmount Modems ...
Страница 22: ...Installation 18 V 34bis Series Standalone Rackmount Modems ...
Страница 40: ...Modes and Configurations 36 V 34bis Series Standalone Rackmount Modems ...
Страница 52: ...Modes and Configurations 48 V 34bis Series Standalone Rackmount Modems AT Z0 Tom XXZYY N store Tom ...
Страница 65: ...Modes and Configurations V 34bis Series Standalone Rackmount Modems 61 ...
Страница 118: ...AT and V 25bis Command Sets 114 V 34bis Series Standalone Rackmount Modems ...
Страница 128: ...S Registers 124 V 34bis Series Standalone Rackmount Modems ...
Страница 150: ...Index 146 V 34bis Series Standalone Rackmount Modems ...