AT and V.25bis Command Sets
V.34bis Series Standalone & Rackmount Modems
105
Table 6.2: Details Continued
n = 0
- Direct
Mode
n
= 1
- (Default) Normal Mode
n = 2
- Automatic Mode
n = 3
- Exclusive Mode. This is the same as automatic mode (n=2),
except that the modem hangs up if a LAPM/MNP link is not
established
Note: If the *M0 command is used, then there will be no response to the
escape code ("+++") and no response to flow control.
*Nn Modem/DTE Speed in Connect
Message
FORMAT: AT*Nn
n = 0
- (Default) Connect message reports modem speed
n = 1
- Connect message reports the DTE speed
*O
Originate LAPM/MNP Link
FORMAT: AT*O
*Pn Maximum Packet Size
FORMAT: AT*Pn
n = 0
- 32 bytes
n = 1
- 64 bytes
n = 2
- 128 bytes
n = 3
- (Default) 256 bytes
*RBn Remote Overflow Bell
FORMAT: AT*RBn
n = 0
- (Default) Disabled
n
= 1
- Enabled
*RFn Filter Receive Flow Control
FORMAT: AT*RF
n
n = 0
- (Default) Disabled - XON/XOFF passed through
n
= 1
- Enabled - XON/XOFF not passed through
Note: This option can be enabled only when the "Respond to Remote
Flow Control" option is enabled by the AT*RR1 command
*RGn Generate Remote Flow Control
FORMAT: AT*RGn
n
= 0
- (Default) No flow control
n
= 1
- XON/XOFF
*RKn Pass Receive Break
FORMAT: AT*RKn
n = 0
- Break disabled
n = 1
- (Default) Receive break immediately
n
= 2
- Receive break after data
*RPn RTS Polarity
FORMAT: AT*RPn
Содержание V.34bis series
Страница 10: ...Introduction 6 V 34bis Series Standalone Rackmount Modems ...
Страница 22: ...Installation 18 V 34bis Series Standalone Rackmount Modems ...
Страница 40: ...Modes and Configurations 36 V 34bis Series Standalone Rackmount Modems ...
Страница 52: ...Modes and Configurations 48 V 34bis Series Standalone Rackmount Modems AT Z0 Tom XXZYY N store Tom ...
Страница 65: ...Modes and Configurations V 34bis Series Standalone Rackmount Modems 61 ...
Страница 118: ...AT and V 25bis Command Sets 114 V 34bis Series Standalone Rackmount Modems ...
Страница 128: ...S Registers 124 V 34bis Series Standalone Rackmount Modems ...
Страница 150: ...Index 146 V 34bis Series Standalone Rackmount Modems ...