Page 23 of 46
When fitting the gas supply note to maintain a good standing pressure we
recommend that a 22mm supply be piped in as close as possible with a
reduction down to 8mm diameter copper pipe (no longer that 1 meter in
length – gas supply to the burner unit) must be installed, the gas supply
pipe should run into the installed burner unit from or left / right hand sides
of the burner unit.
Additionally a 240volt 3amp fused spur power supply should be installed
within or next to the fire opening; this will be the power source for the
remote control system. At this stage a provision for the hard wire switch
position should be considered.
The steel frame/burner unit is then positioned so that the front edge is
positioned as per the fascia type to be fitted
(see page 12).
Once the
steel frame/burner is correctly positioned it is then fixed using fixing
screws, which pass through the frame into the newly built fire opening
brickwork. The Enclosure must be secure and unable to move. The air
intake area at the front of the fire must be left open.
NOTE:
Great care must be taken when inserting the shelves to avoid
scratching the inside of the metal enclosure.
The gas and electric supply is now connected and the burner unit is to be
tested for safe operation. The hard wire switch cabling also needs to be
routed.
Содержание Double Sided Fire Ribbon
Страница 18: ...Page 18 of 46 Fitting the Enclosure...
Страница 19: ...Page 19 of 46...
Страница 20: ...Page 20 of 46...
Страница 21: ...Page 21 of 46...
Страница 22: ...Page 22 of 46...
Страница 28: ...Page 28 of 46 Guidance on Ventilation and Sealing...
Страница 32: ...Page 32 of 46 Remote Control Components Black Box Remote Valve NG Version LPG Version...
Страница 34: ...Page 34 of 46 NG Remote Wiring Diagram...
Страница 35: ...Page 35 of 46 LPG Remote Wiring Diagram...
Страница 39: ...Page 39 of 46...