Page 16 of 46
Builders Opening / Wall Depth
IMPORTANT – Before commencing any work check the type of
fascia to be fitted.
The Enclosure has a total depth of 490mm. The actual wall depth is
decided by the type of fascia to be fitted.
For a Stone Fascia
the enclosure front edge must sit 20mm
out from the finished wall.
For a Metal Fascia
the enclosure front edge must sit flush with the
wall, regardless of the type of enclosure.
Examples:
Fire fitted with 2 x stone fascia
– wall depth (finished face to finished
face – without fascia) – 450mm.
Fire fitted with 2 x metal fascia
– wall depth (finished face to finished
face – without the fascia) – 490mm
Fire fitted with 1 x stone fascia & 1 x metal fascia
– wall depth
(finished face to finished face – without fascia) – 470mm.
This wall depth is critical to ensure the fire fits correctly and performs as
designed.