INITIAL SET UP
FOLLOW THESE STEPS BEFORE YOU USE THE CRIMPER
FOR THE FIRST TIME.
• Mount the crimper on a sturdy workbench in a well-lit area. Workbench
should be able to support the crimper and components weight.
Note:
The D105 series can be mounted on the D-Series Drawer/Stand
and bolted onto the workbench. (See detailed instructions included with
D-Series Drawer/Stand).
• The crimper should be mounted close enough to the edge of the
work surface so that hose will not contact the bench or work surface
while crimping. There must be enough clearance for the hose to align
perpendicular with the cone base, or the dies will not seat properly and
the crimps will not be accurate.
• Always check oil level in the D105 pump, should be 1-1/2 to 2 inches
below the vent plug when the cylinder is in the retracted position and
should be visible in the sight glass window of the pump reservoir.
• If oil needs to be added use ISO 46 weight hydraulic oil.
• Oil can be drained from the rear oil port of the reservoir.
• Check to be certain that the shipping plug in the pump reservoir
has been replaced with the vent plug shipped with the D165 crimper.
• Check electrical circuit to be certain that it matches the crimper
requirements shown on the voltage tag attached to the crimper cord.
• Plug the D105 crimper directly into a 110 volt, 15 amp wall outlet.
Note:
The optional 220 volts / 2HP unit must be connected to a 220 volts
20 amp wall outlet.
Note
: Use of extension cords or outlets with inadequate power can damage
the motor or crimper controls.