**DIAGNOSTICS**
For Qualified Technician Use Only:
(1)Power Ventilation Auxilary SWX:
(2)Ignore Inlet #1 Auxiliary SWX = Yes
(3)Ignore Inlet #2 Auxiliary Swx = Yes
(4)Natural Ventilation Auxiliary SWX:
(5)Ignore Unit #1 Auxiliary SWX = Yes
(6)Ignore Unit #2 Auxiliary Swx = Yes
(7)Ignore Unit #3 Auxiliary Swx = Yes
(8)Ignore Unit #4 Auxiliary Swx = Yes
(9)Feed Level Sensor:
(10)Maximum Range = 26.00 ft
(11)Dead Zone = 1.50 ft
(12)Soft Resets = 0
(13)Voltage Resets = 0
(14)Hard Resets = 0
(15)
Temp 1: 255
Outside:
255
Temp 2: 255
Humidity 1: 0
Temp 3: 255
Humidity 2: 0
Temp 4: 255
Feed 1:
0
Temp 5: 255
Feed 2:
0
Temp 6: 255
GP 1:
0
Temp 7: 255
Temp 8
255
Vent Opened:
No
Water 1:
Yes
Tunnel Closed:
No
Water 2:
Yes
Curt 1 Closed:
No
Run 1:
Off
Curt 2 Closed:
No
Run 2:
Off
Curt 3 Closed:
No
Curt 4 Closed:
No
**Password Setup**
Enter a new password for this
controller and press ENTER:
New Password: 0000
(1) Seasonal Programs –
Select Program 0, 1, 2, 3, or 4 for the current operating program.
This selection can also be used to COPY FROM the Seasonal Program number to the selected program
number shown in the item 3 below.
(2) Program Name –
The program name can be changed to include a special title, letters, numbers, and
characters up to 8 digits in length.
(3) Copy to Program –
Enter the COPY TO program number (0, 1, 2, 3, or 4).
(4) Enter to Proceed –
When “Enter to Proceed” is selected and the ENTER button is pressed, the Copy to
Program number programming contents is replaced with the programming contents of the Seasonal
Program number.
NOTE:
This action is not reversible.
(5) Change Password –
Select “Change Password” for
changing the existing password for the Controller. The
four digits will allow a numeric password from 0001 to
9999. Changing the Password to 0000 disables the locks
until the password is changed to a number between 0001
and 9999.
NOTE:
Record the password in a convenient retrievable location
.
7.15 Diagnostics
The Diagnostics screen is for qualified
technician use only and can only be changed by
using the service code. Contact the local dealer
for assistance.
(1)
Power Ventilation Auxiliary SWX -
Setting these options to Yes will ignore
the indication from the curtain switch.
This feature will totally ignore the
auxiliary switches on the PT machines
when answered yes.
(2)
Ignore Inlet #1 Auxiliary Switch -
Yes
or No
(3)
Ignore Inlet #2 Auxiliary Switch -
Yes
or No
(4)
Ignore Inlet #3 Auxiliary Switch -
Yes
or No
(5)
Ignore Inlet #4 Auxiliary Switch -
Yes
or No
(6)
Natural Ventilation Auxiliary SWX -
Setting these options to Yes will ignore
the indication from the curtain switch.
This feature will totally ignore the
auxiliary switches on the PT machines
when answered "Yes".
Note:
The auxiliary switches must be
connected and this answered to no in
order for the control to enter into natural
ventilation.
(7)
Ignore Unit #1 Auxiliary Switch -
Yes or No
(8)
Ignore Unit #2 Auxiliary Switch -
Yes or No
(9)
Feed Level Sensor
– Settings for setting the maximum range and calibration of the feed level sensor.
(10)
Maximum Range -
Total sensing range of the sensor.
(11)
Dead Zone -
Distance from the top of the feed bin to the bottom of the sensor.
(12)
Soft Resets -
For HHI Use Only. Indicates that the control is sensing environmental problems which
can cause controller malfunctions.
(13)
Voltage Resets -
For HHI Use Only.
(14)
Hard Resets -
For HHI Use Only.
(15)
Analog and Digital Input Status – For HHI Service Technician Use ONLY.