Part No. 4801-5338 Rev 2-2015
Evolution 4000
46 of 86
**PROGRAMS & SECURITY**
(1)Seasonal Program = 1
(2)Program Name = PROGRAM1
(3)Copy to Program = 2 (4)Enter to Proceed
(5)Change Password
**LIGHT CLOCK SETUP**
(1)Feed Cycle Light Override = No
(2)Feed Cycle Light Intensity = 25%
(3)Growout Schedules used by Ramp 1-4
(4)SCHEDULE (5)START DAY
1
1
2
17
3
19
4
22
5
25
(1)Light Schedule: 4
(2)Start Day = 22
(3)Number of On/Off Cycles = 4
(4)CYCLE (5)START (6)RUNTIME (7)INTENSITY (8)RAMP
1
12:00a 2:00 75% 0:10
2
10:00a 2:00 100% 0:10
3
5:00p 2:00 100% 0:10
4
10:00p 2:00 100% 0:10
7.13 Setup Light Clocks
The Light Clock Setup establishes the parameters
necessary to enable automatic control of the house
lights. On each Schedule you will need to program
a start day of when you want the control to start
using this schedule. Then you will need to set the
number of on/off cycles. This is how many times
the light clock needs to come on in a 24-hour
period. You are allowed 10 on/off cycles. Then
you set the start time of each cycle and how long
that cycle needs to run. When you are using a
variable speed stage for the lights you are allowed
to set the intensity and ramp. The intensity is the
level you want the lights to be on when your cycle
comes on. The ramp allows the light ramp up and
down from off to the intensity you have set. The
ramp applies at the beginning and the ending of the
light cycle.
(1) Feed Cycle Light Override -
Turns the lights to a set intensity while running the feed program.
(2) Feed Cycle Light Intensity –
Set the light intensity percentage to occur during the feed cycle.
(3) Growout Schedules used by Ramp 1-1
- Set the number of schedules from one up to five. The next
schedule will start after you have reached the growout day that your schedule starts on.
(4) Schedule –
The schedule number will automatically be set by Evolution. After the number of Schedules
have been set you will need to setup each schedule.
(5) Start Day
–The starting day of each schedule.
7.13.1 Light Clock Details
Select the individual cycle in the Light
Clock Details screen and enter the start
day time that lighting is to begin and the
length and intensity of the lighting
period. This screen is also available
from the Target Conditions screen as
described in
Section 6.2
.
(1)
Light Schedule –
The selected
schedule.
(2)
Start Day –
Set to the growout day to start program.
(3)
Number of On/Off Cycles –
Enter the number of On/Off cycles desired (up to ten).
(4)
Cycle –
The selected cycle within the schedule.
(5)
Start –
The start time of the lighting cycle.
(6) Runtime-
The runtime of the lighting cycle. (hours : minutes)
(7) Intensity –
Set the intensity of the lights from 0% to 100%. (For use with variable units only).
(8) Ramp –
If it is desired to ramp the lights, that is to slowly turn the lights on and off, enter the time period
(hours:minutes) over which to turn the lights on and off (For use with variable units).
7.14 Seasonal Programs & Security
The Seasonal Programs & Password Setup
screen is used to change programs, copy the
settings of one program into another program
or set the password to access applicable
screens.