Part No. 4801-5338 Rev 2-2015
Evolution 4000
25 of 86
6.5.7 Feed History
This screen shows the estimated
daily amount of feed used and the
total time that the feed line motors
have been running.
(1) Day –
The specific day in the
growout period. Values =
1 to 99 days.
(2) Usage –
The amount of feed
used from Bin #1 and Bin
#2 combined for each day
of growout. Measurements
= pounds (lb.).
(3) Run 1 –
The total amount of run-time feed line #1 was running for each day of growout. Measurements
= Hours and minutes.
(4) Run 2 –
The total amount of run-time feed line #2 was running for each day of growout. Measurements
= Hours and minutes.
(5) Status –
The status of the auger current sensor whether the sensor is On or Off. ON indicates the motor
is running and OFF indicates the motor is not running.
6.6
Alarm Status
– MAIN SYSTEM
The ALARM column lists the elements and sensors that are available. For the High and Low temperatures
and High and Low pressure, the Cycle Pressure the current Alarm Limits are shown. For all entries the
STATUS and the LAST REPORTED alarm are indicated. To change the ALARM LIMIT use the Editor
arrows to highlight the desired entry and the Plus (+) and Minus (-) buttons to increase or decrease the
desired limit.
(1)Day
(2)Usage
(3)Auger1
(4)Auger2
(5)Status
On
On
41
2100 lb
4:10
9:10
40
2000 lb
3:00
8:00
.
.
.
.
35
1500 lb
3:00
8:00
.
.
.
.
.
.
.
.
24
1000 lb
1:30
6:30
.
.
.
.
.
.
.
.
1
150 lb
1:10
6:10
NOTE: The High and Low
temperature reading is taken from
the Sensors for Display in "Sensor
Setup" of the Program Setup Screen.
Proceed
to Detail
Screens
TEMPERATURE
LIMIT
STATUS
LAST ALARM
(1)High Temp
85.0
°
OK 08/15-10:36p
(2)Low Temp
65.0
°
OK
08/10-03:36p
PRESSURE
LIMIT
STATUS
LAST ALARM
(3)Cycle Press
0.04
Off
08/09-07:36p
(4)High Press
0.15
Off
07/22-01:36p
(5)Low Press
0.03
Off
07/13-06:36p
WATER ALARMS
LIMIT
STATUS
LAST ALARM
(6)High Rate #1
100/hr
OK
01/01-12:00a
(7)Low Rate #1
25/hr
OFF
01/01-12:00a
(6)High Rate #2
100/hr
OK
01/01-12:00a
(7)Low Rate #2
25/hr
OFF
01/01-12:00a
FEED ALARMS
LIMIT
STATUS
LAST ALARM
(8)Auger Run1
10min
OFF
01/01-12:00a
(9)Auger Run2
10min
OFF
01/01-12:00a
SYSTEM STATUS
STATUS
LAST ERROR
(10)Tunnel Vent
----
OK
07/12-02:36p
(11)Growout Day
----
OK
07/31-05:36p
(12)Local Network ----
OK
07/27-05:36p
(13)Back-Up Limits ----
OK
07/31-05:36p
(14)Sensor 1
----
OK
07/27-05:36p
(14)Sensor 2
----
OK
06/10-09:36p
(14)Sensor 3
----
OK
06/11-01:36p
(14)Sensor 4
----
OK
06/13-06:36p
(14)Sensor 5
----
OK
06/13-03:36p
(14)Sensor 6
----
OK
06/21-03:36p
(14)Sensor 7
----
OK
06/17-02:36p
(14)Sensor 8
----
OK
06/13-10:36p
(15)Outside
----
OK
07/13-02:31p