Part No. 4801-5338 Rev 2-2015
Evolution 4000
44 of 86
** Natural Ventilation Properties **
The Natural Ventilation Stages typically
operate sidewalls. The following are some
additional properties:
(1)Time Override:
Allow to Operate Always
Time falls between 5:00p - 5:00a
(2)Growout Day Override:
Allow to Operate Only While
Growout Day > 7
(3)Outside Temperature Override
Allow to Operate Always
Outside Temperature > 10.2°
** Cool Evaporative Properties **
These stages typically operate
Evaporative Cooling Systems. The
following are additional properties:
(1)Only Operate During Tunnel Vent = No
(2)Time Override:
Allow to Operate Always
Time falls between 12:00p - 5:00p
(3)Humidity Override:
Allow to Operate Always
Humidity < 75%
(4)Growout Day Override:
Allow to Operate Always
Growout Day > 14
(5)Outside Temperature Override
Allow to Operate Always
Outside Temperature > 10.2°
7.11.6 Cool Evaporative Properties
Cool Evaporative Properties allow for setting several override functions. Take note when setting the
properties. All options must be true before the stage is allowed to operate.
For example if all options are set to Only While, then all options will have to be true or in the range before the
stage is allowed to operate.
(1) Only Operate During Tunnel Vent
–Setting this to “Yes” will only
allow the evaporative cooling
stages to operate during tunnel.
Otherwise on “No” will allow
the stages to operate while not
in tunnel. For example on
misting Hogs during natural
ventilation.
(2) Time Override –
When set to Only
While, the Time Override will
allow the stages to operate only
while the time is between the
times you set. Otherwise when
set to Always, the time will not
affect the stages.
(3) Humidity Override -
Run while
humidity is less than XX%.
When set to Only While, the Humidity Override will allow the stages to operate only while the
humidity is less than the humidity you set. Otherwise when set to Always, the humidity will not
affect the stages.
(4) Growout Day Override -
When set to Only While, the Growout Day Override will allow the stages to
operate only while the growout day is greater than the day you set. Otherwise when set to Always,
the day of growout will not affect the stages.
(5) Outside Temperature Override -
When set to Only While, the Outside Temperature Override will allow
the stages to operate only while the outside temperature is greater than the target plus or minus the
desired setting. Otherwise when set to Always, the outside temperature will not affect the stages.
7.11.7 Natural Ventilation Properties
(1) Time Override
- When set to Only
While, the Time Override will
allow the Natural Curtain Stages to
open while the time is between the
times you set. Otherwise when set
to Always, the time will not affect
the Natural Curtain Stages.
(2) Growout Day Override
- When set to
Only While, the Growout Day
Override will allow the Natural
Curtain stages to operate only while
the growout day is greater than the
day you set.
Otherwise when set to Always, the
day of growout will not affect the
stages.
(3) Outside Temperature Override
- When set to Only While, the Outside Temperature Override will allow
the stages to open only while the outside temperature is greater than the target plus or minus the
desired setting. Otherwise when set to Always, the outside temperature will not affect the stages.