Part No. 4801-5338 Rev 2-2015
Evolution 4000
17 of 86
(1)Light Schedule
(2)Feed Schedule
(3)MINIMUM TIMERS:
(4)Cycle= 5 m ( 300s) (8)VARIABLE SPEED:
(5)Min1%= 40% ( 215s) (9)V1 Min%= 50%( 55%)
(6)Min2%= 20% ( 108s) (10)V2 Min%= 40%(100%)
(7)Var%: 20% ( 108s)
(11)VARIABLE TIMER:
(12)Sensors = Outside-
(13)Max Run % = 65%
(14)Max Temp = 85.0°
(15)Min Run % = 20%
(16)Min Temp = 70.0°
(17)COOL TIMER:
(18)Max Run % = 100%
(19)Cycle = 10 m ( 600s)
(20)Min Run % = 55%
NOTE: Cycle in seconds
NOTE: Run Time in seconds
6.3
Timers & Clocks
– MAIN SYSTEM
The Minimum Vent status screen display:
(1) Light Schedule –
Displays the current Light Clock
Schedule. See
Section 7.13
.
(2) Feed Schedule –
Displays the current Feed Clock
Schedule. See
Section 7.12
.
(3) Minimum Timer 1 -
The Minimum timer one and
two both share the same cycle time. Different timer
percentages may be set for minimum 1 vs. minimum
2. If the vent anticipation is being used, the vents
will start opening before a negative ventilation stage
turns on and will adjust until the vent opening
necessary for the desired target pressure is achieved.
(4) Cycle -
The length of Timer 1 cycle. Cycle = 1 to
20 minutes.
(5) Min1 % -
The percentage of the Timer 1 cycle that
the stage will run.
(6) Min2 % -
The percentage of the Timer 2 cycle that
the stage will run.
(7) Var % -
The percentage of time a stage is currently
running using the variable timer based off the
temperature.
NOTE:
The Minimum timer one and two both share
the same cycle time. Different timer percentages
may be set for Minimum 1 and Minimum 2. If the
vent anticipation is being used, both Minimum 1 and
Variable will start the vents open before a stage
comes on.
(8) Variable Speed:
These settings are used to set up
variable speed fan operation.
(9) V1 Minimum -
The minimum speed or minimum
percentage of light intensity for V1; The value
inside the parenthesis shows the current percentage.
(10) V2 Minimum -
The minimum speed or minimum
percentage of light intensity for V2; The value
inside the parenthesis shows the current percentage.
(11) Variable Timer -
The variable timer will vary the
timer based on temperature.
See chart shown
below.
(12) Sensors -
The sensors used to determine the run
time. Active sensors will be indicated by a number
starting with #1 from right to left. Inactive sensors
will be indicated by a - or hyphen. When "outside-"
is displayed, outside sensor is active. For example, If
sensors 1, 2 and 3 are being used, "-----321" will be
displayed. When “outside” is displayed, the outside
sensor is active.
(13) Max Run % -
The maximum Run Time
percentage.
(14) Max Temp -
The temperature at which the timer
will run Maximum Run time % percentage.
(15) Min Run % -
The minimum Run Time
percentage.
(16) Min Temp -
The minimum temperature. The
timer will be at minimum Run %.