Part No. 4801-5338 Rev 2-2015
Evolution 4000
31 of 86
** (1)EV4000 v0.06 ** BV: 4
(2)HHNet Address = 1
(3)Optimum Mode = Off
(3)Growout Start Date = 17 Sep 2009
(4)Preheat Mode = Off
(5)Date = 17 Sep 2009
(6)Day = Thu
(7)Time = 10:30a
(8)Units of Measure = English
(9)Pressure Units = Inches of wc
(10)Water Meter-Pulses Per Unit - 1
NOTE:
This is the timer percentage of the Evolution Back-Up system. This setting is set in the Back-Up
system. This setting is automatically calculated based on the controller target temperature. If the
Back-Up fails to communicate with the Evolution 4000 control the Back-Up will display an LnE.
At this point the Back-Up will take over minimum ventilation by running all Cool 1 circuits on this
timer. This percentage is how long the fan will run out of five minutes.
(5) Cycle 5 Minutes
–The cycle time of the back-up stages is 5 minutes.
(6) Warning if Back-Up –
If Backup settings are set that far away from target, Back-up status light will
flash.
(7) Alarm if Back-Up -
Same as above but will also set off auxiliary alarm contact.
7. Setting Programming Functions
This section discusses the programming screens for the Evolution 4000.
7.1
General Settings
The General Settings contains parameters that usually only need to be set once when the system is installed.
To change any of these parameters, use the EDITOR arrows to navigate through the list and the plus (+) and
minus (-) buttons to increase or decrease the values.
(1)
Software Version
– The “v0.xx” is the software version for PCB197 U8 and “BV: x” is the BootLoader
software version currently in use.
(2)
HHNET Address
- HH.Net permits up to
32 controllers to be addressed on a single
communications port of a personal
computer (PC). In order for the computer
to recognize the communications from the
controllers, each controller must have a
unique network address. For example: If
you have an Evolution 4000, a Stage
Master, and two Power Vents you would
need to set the Evolution to address 1, the
Stage Master to address 2, the first Power
Vent to address 3, and the second Power
Vent to address 4. Valid settings are: 1 -
32. (You do not have to address the
controllers in any particular order.)
(3)
Optimum Mode
– On or Off. Refer to
Section 7.7.2
for a detailed description of
the Optimum Mode features and options.
(4)
Growout Start Date -
Set the date desired
to start the grow-out. Evolution will use this
date to control the feed, light clock and
ramping functions. NOTE: This must be set
to the first day of grow-out. Your historical
data will start at this date and go for 99 days
or until the next grow-out date has been set
and then that date has been passed.
(5)
Preheat Mode
–
On or Off
(6)
Date –
The current date as Day/Month/Year.
(7)
Day –
The current day of the week.
(8)
Time –
The current time.
(9)
Units of Measure -
The units of measure can be
selected as English or Metric.
(10)
Pressure Units -
Pressure units can be selected
as inches of water column or Pascals.
(11)
Water Meter-Pulses Per Unit –
HH standard
water meter is one pulse per gallon. Select a
value from 1 to 100.