![CTS VRG5-31412 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/cts/vrg5-31412-series/vrg5-31412-series_user-manual_2694013067.webp)
67
2.5.14 User Command
User command
Parameter
Description
Gateway(config)# user
name [user_name]
[user_name] Enter the new account
’s username. The
authorized user login name is up to 20
alphanumeric characters. Only 10 login
accounts can be registered in this device.
Gateway(config-user-
NAME)# active
Activate this user account.
Gateway(config-user-
NAME)# description
[description]
[description] Enter the brief description for this user
account.
Gateway(config-user-
NAME)# level [admin | rw |
ro]
[admin | rw |
ro]
Specify this user
’s access level.
admin (administrator):
Full access right,
including maintaining user account & system
information, loading factory settings, etc..
rw (read & write):
Partial access right,
unable to modify user account & system
information and load factory settings.
ro (read only):
Read-Only
access privilege
Gateway(config-user-
NAME)# password
[password]
[password]
Enter the password, up to 20 alphanumeric
characters, for this user account.
No command
Gateway(config)#no user
name [username]
[username]
Delete the specified account.
Gateway(config-user-
NAME)# no active
Deactivate the selected user account.
Gateway(config-user-
NAME)# no description
Remove the configured description.
Gateway(config-user-
NAME)# no password
Remove the configured password value.
Gateway(config-user-
NAME)# no level
Reset access level privilege back to the
factory default (access denied).
Show command
Gateway(config)# show
user name
List all user accounts.
Gateway(config)# show
user name [user_name]
[user_name] Show the specific account
’s information.
Gateway(config-user-
NAME)# show
Show or verify the newly-created user
account
’s information.
User command example
Gateway(config)#user name miseric
Create a new login account
“miseric”.
Gateway(config-user-miseric)#
description misengineer
Add a description to this new account
“miseric”.