2.10.6 Stabilisation control device
Device comprising 2 limit switches on each stabiliser to check for the correct
positioning of each stabiliser on the ground. One limit switch indicates the stabiliser’s
minimum stroke and the other checks that the stabiliser is resting on the ground.
2.10.7 Spirit level
fig. 2.10.5
Situated in proximity of the outriggers control
levers (
pos. 1 fig. 2.10.5
) indicates the horizontally of
the machine.
2.10.8 Outriggers/boom interlock
The sensor and limit switch on the arm rest clamp. Allows activation of the outrigger
controls only when the superstructure is completely closed and the key selector switch
is placed in the "outriggers" position. The outriggers controls are deactivated
automatically when the boom leaves the rest position.
2.10.9 Outriggers end run at rest
One end run over every outrigger. When the stabilisers have fully retracted, the red
indicator light on the cabin panel switches off and the limit switch indicator light ”go”
switches on.
2.10.10 Selection of control board on the ground/on the platform
It prevents the controls from being used at the same time. The control panel in the
platform is active when the ground control panel key selector switch is turned to
“platform”. The platform controls are automatically deactivated by removing the blind
plug (pos. 8 Fig. 2.9.1) located near the ground control panel. Plugging the supplied
portable push-button panel automatically activates its controls.
2.10.11 Basket overload control device
The load cell installed under the basket detects the load present in the basket and if
this should exceed the maximum capacity it blocks the movement of all manoeuvres
(the LED in the basket switches on and an acoustic warning is activated). It is
deactivated by removing the extra load.
1
Содержание ZED 23.2 JH
Страница 1: ...Use and maintenance manual AERIAL WORK PLATFORM ZED 23 2 JH SERIAL N REV 00 ED 12 2014 CODE UM0260_GB...
Страница 2: ......
Страница 13: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 11 2 5 Work area...
Страница 47: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 45...
Страница 50: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 48 7 HYDRAULIC PLANT LAYOUT...
Страница 51: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 49 8 ELECTRIC WIRING DIAGRAM...