38
CTC EcoAir 610M / 614M / 622M 400 V 3N~
1
588693301 Filterkulventil G1"
Reservdelen packas och emballeras väl i lämpligt emballage
Ändr. meddel.
Datum
Nr
Ändring
Ändr. av
Kontr. av
93766
2018-05-30
1
Reservdel tillkom
SJ
JW
Pos nr Antal
Artikel nr.
Benämning
Kommentar
1
1
588574301
Ventil kul filter G1"
DN25
E
art. nr
Utgåva
Ämnes nr
Ersätter
art. nr
Ersättes av
Grupp
Produkt
Reg. nr
Benämning
Tol.system
Kontr.
Normgr.
Skala
Ritad
Material
Datum
Sign.
Distr till/Antal
Ytjämnhet RA
Godk. prod
Om ej annat angives gäller ovanstående
Denna ritning är Enertech AB's egendom.
Den får ej användas till skada för
företagets intressen.
Diese Zeichnung ist das Eigentum der
Enertech AB und darf nicht zum Scha-
den dieser Gesellschaft verwendet
werden.
This drawing is the property of
Enertech AB and is not to be used
against the interest of this com-
pany
1:1
SJ
2018-05-30
Filterkulventil G1
Reservdel
EA600
1
588693
JW
blad 1/2
Operation stop
The heat pump is shut down using the operating switch. If there is a risk of
the water freezing, ensure that there is circulation, or drain out all the water
from the heat pump.
Condensation water tray
The condensation water tray collects water formed on the EcoAir’s
evaporator during operation and defrosting. The condensation water tray is
equipped with an electric heating coil which keeps the tray free of ice when it
is freezing outside. The condensation water tray is located at the bottom on
the back of EcoAir. By lifting the handle on the cover plate and pulling it out,
you can clean and inspect the condensation tray.
As an accessory you can buy a heating cable to connect to EcoAir. The
cable is fitted in the drain from the condensation tray to the frost-free drain.
Condensate tray and drain.
Periodic maintenance
After three weeks of operation and every three months of the first year,
thereafter once a year:
• Check that the installation is free of leaks.
• Check that the product and system are free of air; bleed if needed.
• Check that the evaporator is clean.
• The products do not require annual inspection for refrigerant leakage.
• Clean the filter ball valve located on the heat pump’s return flow.
Refer to the chapter titled “Cleaning the Filter Ball Valve”.
Cleaning the Filter Ball Valve
1.
Turn off the heat pump with the omnipolar switch.
2.
Close the valve (switch to the OFF position) and unscrew the cover
underneath.
3.
Use lock ring pliers to remove the lock ring securing the fi lter.
4.
Remove the fi lter and rinse clean.
5.
Refi t the fi lter and lock ring.
6.
Reattach the cover carefully and make sure to not pinch the O-ring
gasket.
Switch the fi lter ball valve to the “ON”
position.
Содержание 588400001
Страница 2: ......
Страница 32: ...32 CTC EcoAir 610M 614M 622M 400 V 3N 6 9 Wiring diagram 400 V 3N A3...
Страница 33: ...33 CTC EcoAir 610M 614M 622M 400 V 3N...
Страница 34: ...34 CTC EcoAir 610M 614M 622M 400 V 3N 6 10 Wiring diagram 400 V 3N A4...
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 505 89 1 2020 09 14...