CTC EcoAir 610M / 614M / 622M 400 V 3N~
>2 m
>0.25 (610M/614M)
>0.4 m (622M)
>1 m
>0.5 m
>1 m
>0.5 m
(622M)
(610M/614M)
(622M)
(610M/614M)
4.2 Location of the heat pump
• CTC EcoAir 600M is normally placed against an outside wall.
• The heat pump has a factory-fitted condensation water tray from which
condensation water is conducted to a caisson, surface water drain,
downpipe or other drainage equipment. You should therefore consider
the position of the product.
• If the condensation water pipe is not used, the foundation must be such
that condensing water and melted snow can drain into the ground.
Make a 'stone curb' under the heat pump. Remove 70–100 cm and fill
up with crushed stones to obtain the best possible drainage.
• The distance between wall and product is recommended to be at
least 250 mm (EcoAir 610M / 614M) and 400 mm (EcoAir 622M)
respectively, so that the outdoor air can flow through the evaporator
without hindrance.
• Allow a space of at least 2 metres between the heat pump and any
bushes etc.
• Place the heat pump so that noise from the compressor and fan does
not disturb the surroundings.
• Do not place the heat pump right next to a bedroom window, patio or
fence. Consider the distance to the nearest neighbour.
• The stand must stand stably on concrete blocks or similar.
• Use a spirit level to adjust the unit, so that it is completely level.
• Due to the design of the stand and the weight of the pump, it is not
necessary to mount the unit to the ground or the wall.
• Installing the heat pump in a sheltered spot is inadvisable, and so is
placing it in an outhouse or car port. because the air should flow as
freely as possible through the heat pump and used air should not to
be sucked into the inlet on the back. This can cause abnormal ice
formation in the evaporator.
• If the product is located where it will be subjected to particularly harsh
weather conditions, the product can be installed underneath a small
awning.
!
These guidelines
must be followed
in order for your
CTC EcoAir 600M
to give the optimal
performance.
Содержание 588400001
Страница 2: ......
Страница 32: ...32 CTC EcoAir 610M 614M 622M 400 V 3N 6 9 Wiring diagram 400 V 3N A3...
Страница 33: ...33 CTC EcoAir 610M 614M 622M 400 V 3N...
Страница 34: ...34 CTC EcoAir 610M 614M 622M 400 V 3N 6 10 Wiring diagram 400 V 3N A4...
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 012 162 505 89 1 2020 09 14...