23. Maintenance  check  lists

 

 

 

Only  authorised  and  qualified  staff  are  permitted  to  carry  out  the  following  work!

 

 

Time 
interval*

 

Cleaning  and  operating  instructions

 

(Always  disconnect  mains  supply  plug  before  performing  any  work  on  the  device!)

 

Every day

 

  Visual  check  of  water  level  via  LED  display  (10-50)  litres. Device  switches  off  automatically 

at residual water level of approx. 15 litres.

 

 Does not apply in case of automatic water supply.

 

  Visual  check  of  indicated  humidity  value  via  digital  display.

 

3-5

 

weeks

 

  Lift upper part of device upwards.

 

  Visual check of filter. In case of strong pollution replace filter. (Use original filters only, other- 

wise  operation  of  the  device  may  be  impaired).  When  inserting  the  new  filter,  always  take 
care that it will be inserted flush with water distribution system (see operation manual 

„Re- 

placing 

filters“).

 

 The  two lateral  snap bows of the  filter  must  be inserted properly, since  otherwise  the  filter

 

can  come  into  contact  with  the  upper  part  of  the  casing, which  may  cause  water  escapes.

 

  Please  check  at  the  same  time  whether  the  outlet  holes  in  the  water  distribution  system  are 

free  from  residues.  Remove  any  residues  such  as  lime  or  dust  for  instance,  by  means  of  a 
needle, a screwdriver or even use a vacuum cleaner for this.

 

  Lift middle part of device off in upward direction.

 

  Remove  remaining  water  from  the  water  container  and  clean  the  tub  (bottom  part).

 

 This is necessary in particular when using fresh water in order to avoid higher concent- 

rations of residues.

 

  Visual  check  of  the  copper  electrode  bars  (see  operation  manual).  Remove  lime  and  other 

residues by means of a household sponge, or if necessary use a rag for this.

 

12-16

 

weeks

 

  As described in the above section the filter must be replaced after 12 to 16 weeks in any 

case,  since  otherwise the operation  of the  device  may  be  impaired. When replacing the filter 
check the water distribution for passage.

 

  After  this  time  has elapsed and in  case of heavy  calcification  and  dirt  deposits  the water tub 

(bottom part)  should be  cleaned by  means of an  anti-lime agent  from an anti-lime agent  that 
is  customary  in  the  trade. After  cleaning  with  such  an  agentalways  rinse  the  water  tube  well 
in order to avoid residues remaining in the device.

 

12

 

months

 

  General cleaning of  the  device by  means  of anti-lime agent

 

- clean pump  tubes  using a bottle  brush or replace  them

 

- clean the body of the fan by using the extension nozzle of the vacuum cleaner

 

- clean the body of the pump

 

- clean  the  copper  electrodes

 

Содержание B500

Страница 1: ......

Страница 2: ...gy with calcium conversion cartridge B 14 Changing the UV tubes B 14 21 Parts list B 15 22 Design Exploded view drawing B 16 23 Maintenance check lists B 17 24 Correcting faults B 19 25 Installation suggestions B 20 26 Technical d a t a B 21 m Before you commission your new equip ment please read through the operating in structions Commissioning Check List Within the equipment are the accessories ...

Страница 3: ...er change indicator Electronic water level indicator Fan speed indicator Automatic fan Actual required atmospheric humidity dis play Menu in programming mode or Fault code with error message Error message display note fault code The electronic hygrostat radio sensor system auto matically controls the humidifier The required humid ity values can be set by means of the remote control m Disconnect th...

Страница 4: ...r level is indicated by light emitting diodes max 5 stages Both normal tap water and softened water can be used to operate the humidifier m Do not use distilled water Take care to fill correctly since spilt water could enter the equipment and cause a short circuit The maximum temperature of the water must not exceed 35 C The water level is sensed by copper electrodes and is indicated by LEDs on th...

Страница 5: ...n of the housing thus causing leaks m Before doing any work on the appliance always make sure it is unplugged from the wall socket In the event of a defect in the control panel it may be necessary to replace it completely Please proceed as follows 1 Raise the upper part of the housing 2 Loosen the four screws on the corners of the con trol panel and take the panel out 3 Unplug the plugs 1 2 X9 vfr...

Страница 6: ... its own speed depending on the output required It does this by measuring the changes in atmospheric humidity and increasing or decreasing the fan speed accordingly To activate the automatic fan press the side of the Fan button and hold it down until the last bar has disappeared from the indicator and the red diode with the fan symbol has gone out To deactivate it simply increase the fan speed wit...

Страница 7: ...toryadjusted to 2 14 Coding the radio sensor system Coding the sensor These appliances are coded in the factory but if two or more are used in direct proximity to one another i e less than 50 metres apart a different coding may be necessary For each slide control there are only two positions ON up and 0FF down which give 16 possible combinations Please note each appliance and its ra dio sensor a b...

Страница 8: ...s setting yourself Please refer to the section on Menu programming The following fault codes tell you what problem has occurred and what has to be done m If a fault code is displayed only the On Off button and the PROG and SET key on the re mote control unit can be used Fault code Fault What to do 01 Water tank is empty Check water level and top up if necessary Check water level diodes for dirt an...

Страница 9: ...ve humidi ty The programming process can be termi nated at any time by pressing the ON OFF button Please note however that this will result in the loss of all the changes that have been made 10 Hooter setting 11 Hooter active when tank 00 OFF empty 01 ON 01 12 Hooter active when UV 00 OFF Only at version with lamp is defective 01 ON UV C technology 01 13 Hooter active with external 00 OFF With ext...

Страница 10: ... switch or other 230V 01 ON switching mechanism REQUIRED humidity level is fixed at 90 The ACTUAL display shows a constant 00 rF The fan can be set freely at any suitable speed 00 35 Setting Changing interval of the fan in auto mode 01 10 min Dependent on the size of the room The immersion pump can be removed from the centre plate by turning it in the direction indicated by the arrow Take particul...

Страница 11: ...ection to the local water main must be made by a qualified specialist i e a licensed installation tech nician Please note the water supply utility s regula tions It may be advisable to fit a back flow stop valve We recommend our 1 5 metre long safety pressure hose for the connection between the water pipe and the appliance Product no 1754 The automatic sys tem for topping up the water incorporates...

Страница 12: ...ly removed from the clips The service life is approx 6 months which primarily depends on the dirt in the room air e g smoke and dust accumulation Air scoop with flexible hose These accessories are especially used in church or gans The scoop is fitted or screwed to the outlet of the B 500 Provided with a flexible aluminium ventila tion hose 150 mm which carries the humidified air into the critical ...

Страница 13: ...perly and insert it into the glass tube again with care The UV lamp is to be disposed of in accordance with legal requirements The UV tube has an operating life of about 5000 hours m Please take care that the quartz glass body in which the source sits is not damaged when fitting and removing the UV source All accessories can be retrofitted at any time at the factory or by an authorised dealer m In...

Страница 14: ...ypad foil 1401 Water distribution 1402 Stick on part extension left 1403 Stick on part extension right 1406 Remote control 1411 Filter rods without grooves 6 1412 Filter rods with grooves 4 1413 Clamp bracket with double nib 1500 Fan complete with motor housing and 1507 mounting parts Fan housing 1508 Sheet metal screw M 4 2 x 19 A2 4 1518 Plug body with cable 1520 Gum metal bumper M 4 1522 1 High...

Страница 15: ...22 Construction ...

Страница 16: ... residues such as lime or dust for instance by means of a needle a screwdriver or even use a vacuum cleaner for this Lift middle part of device off in upward direction Remove remaining water from the water container and clean the tub bottom part This is necessary in particular when using fresh water in order to avoid higher concent rations of residues Visual check of the copper electrode bars see ...

Страница 17: ... cartridge Lift the centre plate upwards out of the water tank lower part The UV degermination arrangement is located below the centre plate next to the pump Inspect stainless steel tube visually and remove fouling Withdraw pump hoses from the stainless steel tube and check the passage of the stainless steel tube hoses Remove fouling Take care that the quartz glass body is not damaged The lime con...

Страница 18: ...ectly installed Renew filter Check the filter seating Water degermination moni tor lamp does not light 1 UV source defect Replace UV source Device does not respond to the remote control Battery discharged or incorrectly installed Distance between remote control and device too great Check battery and replace note Reduce distance Automatic water feed no longer replenishes water 2 Safety pressure hos...

Страница 19: ... must be taken to ensure that adequately large openings are available for air intakes and outlets to ventilate the appliance Living room area Equipment in a specialist shop walk in humidor Possible uses in the museum area or in churches to protect valuable organs 25 Installation suggestions ...

Страница 20: ...ent Air flow capacity 900 m h Evaporation capacity 2 6 ltr h on 25o C and 20 r H Evaporation filter area 3 5 m Weight empty approx 24 kg Water reservoir approx 50 ltr Dimensions L 75 5 x H 62 0 x W 36 5 cm m Disconnect the mains plug before openingthe equipment 26 Technical data ...

Отзывы: