25

 

Relay active when no radio 
signal

 

00 = OFF

 

01 = ON

 

Only necessary with connection to a 
central air-conditioning system

 

 

00

 

 

26

 

Relay switch status 
(Low= Relay active open

 

High= Relay active closed)

 

00 = OFF

 

01 = ON

 

Only necessary with connection to a 
central air-conditioning system

 

 

00

 

 

 

30 

Rinsing setting

 

31

 

Rinse cycle in days

 

00 = OFF

 

(manuell)

 

01 ... 07 days

 

If rinsing is existent

 

 

 

07

 

32

 

Water hardness setting

 

01 = soft

 

02 = medium

 

03 = hard

 

Water  hardness  affects  the  filter 
change display interval

 

02

 

33

 

Resetting  the  filter 
change indicator

 

98 = reset

 

The display „98 - .00” shows in how 
many days the filter will have to be 
changed. The display can be reset to 
98 days at any time

 

98

 

34 

Operation via  external  00 = OFF 
time switch or other 230V  01 = ON

 

  

switching mechanism 

 

  

 

REQUIRED humidity level is fixed at 
90%. The ACTUAL display shows a 
constant 00%rF. The fan can be set 
freely at any suitable speed

 

 

00

 

35

 

Setting/Changing  interval 
of the fan in auto-mode

 

01 

… 10 min.

 

Dependent on the size of the room

 

 

 

 

 

The immersion pump can be removed from the centre 
plate  by  turning  it  in  the

 

direction indicated  by the 
arrow.  Take  particular 
care  when  installing  the 
pump to ensure that the 
plug connection as well as 
the pump hoses and the 
Y-piece, or on devices with 
UV-technology the connec- 
tion hoses to the V4 A-pipe, 
are firmly fitted.

 

To prevent the development of germs, algae, mould 
or  bacteria  and  the  odours  they  cause  in  the  water 
container of a humidifier, we recommend the use of 
adequate  hygiene  products

 

such as LiQVit and Secosan. 
Secosan  can  be  placed  di- 
rectly  in  the  water  container. 
When  exchanging  the  water 
in the reservoir, simply take 
it  out  and  the  Secosan  Stick 
can  be  used  again.  Depend- 
ing  on  the  volume  of  the

 

18. Hygiene  products

 

17. Water pump

 

Содержание B500

Страница 1: ......

Страница 2: ...gy with calcium conversion cartridge B 14 Changing the UV tubes B 14 21 Parts list B 15 22 Design Exploded view drawing B 16 23 Maintenance check lists B 17 24 Correcting faults B 19 25 Installation suggestions B 20 26 Technical d a t a B 21 m Before you commission your new equip ment please read through the operating in structions Commissioning Check List Within the equipment are the accessories ...

Страница 3: ...er change indicator Electronic water level indicator Fan speed indicator Automatic fan Actual required atmospheric humidity dis play Menu in programming mode or Fault code with error message Error message display note fault code The electronic hygrostat radio sensor system auto matically controls the humidifier The required humid ity values can be set by means of the remote control m Disconnect th...

Страница 4: ...r level is indicated by light emitting diodes max 5 stages Both normal tap water and softened water can be used to operate the humidifier m Do not use distilled water Take care to fill correctly since spilt water could enter the equipment and cause a short circuit The maximum temperature of the water must not exceed 35 C The water level is sensed by copper electrodes and is indicated by LEDs on th...

Страница 5: ...n of the housing thus causing leaks m Before doing any work on the appliance always make sure it is unplugged from the wall socket In the event of a defect in the control panel it may be necessary to replace it completely Please proceed as follows 1 Raise the upper part of the housing 2 Loosen the four screws on the corners of the con trol panel and take the panel out 3 Unplug the plugs 1 2 X9 vfr...

Страница 6: ... its own speed depending on the output required It does this by measuring the changes in atmospheric humidity and increasing or decreasing the fan speed accordingly To activate the automatic fan press the side of the Fan button and hold it down until the last bar has disappeared from the indicator and the red diode with the fan symbol has gone out To deactivate it simply increase the fan speed wit...

Страница 7: ...toryadjusted to 2 14 Coding the radio sensor system Coding the sensor These appliances are coded in the factory but if two or more are used in direct proximity to one another i e less than 50 metres apart a different coding may be necessary For each slide control there are only two positions ON up and 0FF down which give 16 possible combinations Please note each appliance and its ra dio sensor a b...

Страница 8: ...s setting yourself Please refer to the section on Menu programming The following fault codes tell you what problem has occurred and what has to be done m If a fault code is displayed only the On Off button and the PROG and SET key on the re mote control unit can be used Fault code Fault What to do 01 Water tank is empty Check water level and top up if necessary Check water level diodes for dirt an...

Страница 9: ...ve humidi ty The programming process can be termi nated at any time by pressing the ON OFF button Please note however that this will result in the loss of all the changes that have been made 10 Hooter setting 11 Hooter active when tank 00 OFF empty 01 ON 01 12 Hooter active when UV 00 OFF Only at version with lamp is defective 01 ON UV C technology 01 13 Hooter active with external 00 OFF With ext...

Страница 10: ... switch or other 230V 01 ON switching mechanism REQUIRED humidity level is fixed at 90 The ACTUAL display shows a constant 00 rF The fan can be set freely at any suitable speed 00 35 Setting Changing interval of the fan in auto mode 01 10 min Dependent on the size of the room The immersion pump can be removed from the centre plate by turning it in the direction indicated by the arrow Take particul...

Страница 11: ...ection to the local water main must be made by a qualified specialist i e a licensed installation tech nician Please note the water supply utility s regula tions It may be advisable to fit a back flow stop valve We recommend our 1 5 metre long safety pressure hose for the connection between the water pipe and the appliance Product no 1754 The automatic sys tem for topping up the water incorporates...

Страница 12: ...ly removed from the clips The service life is approx 6 months which primarily depends on the dirt in the room air e g smoke and dust accumulation Air scoop with flexible hose These accessories are especially used in church or gans The scoop is fitted or screwed to the outlet of the B 500 Provided with a flexible aluminium ventila tion hose 150 mm which carries the humidified air into the critical ...

Страница 13: ...perly and insert it into the glass tube again with care The UV lamp is to be disposed of in accordance with legal requirements The UV tube has an operating life of about 5000 hours m Please take care that the quartz glass body in which the source sits is not damaged when fitting and removing the UV source All accessories can be retrofitted at any time at the factory or by an authorised dealer m In...

Страница 14: ...ypad foil 1401 Water distribution 1402 Stick on part extension left 1403 Stick on part extension right 1406 Remote control 1411 Filter rods without grooves 6 1412 Filter rods with grooves 4 1413 Clamp bracket with double nib 1500 Fan complete with motor housing and 1507 mounting parts Fan housing 1508 Sheet metal screw M 4 2 x 19 A2 4 1518 Plug body with cable 1520 Gum metal bumper M 4 1522 1 High...

Страница 15: ...22 Construction ...

Страница 16: ... residues such as lime or dust for instance by means of a needle a screwdriver or even use a vacuum cleaner for this Lift middle part of device off in upward direction Remove remaining water from the water container and clean the tub bottom part This is necessary in particular when using fresh water in order to avoid higher concent rations of residues Visual check of the copper electrode bars see ...

Страница 17: ... cartridge Lift the centre plate upwards out of the water tank lower part The UV degermination arrangement is located below the centre plate next to the pump Inspect stainless steel tube visually and remove fouling Withdraw pump hoses from the stainless steel tube and check the passage of the stainless steel tube hoses Remove fouling Take care that the quartz glass body is not damaged The lime con...

Страница 18: ...ectly installed Renew filter Check the filter seating Water degermination moni tor lamp does not light 1 UV source defect Replace UV source Device does not respond to the remote control Battery discharged or incorrectly installed Distance between remote control and device too great Check battery and replace note Reduce distance Automatic water feed no longer replenishes water 2 Safety pressure hos...

Страница 19: ... must be taken to ensure that adequately large openings are available for air intakes and outlets to ventilate the appliance Living room area Equipment in a specialist shop walk in humidor Possible uses in the museum area or in churches to protect valuable organs 25 Installation suggestions ...

Страница 20: ...ent Air flow capacity 900 m h Evaporation capacity 2 6 ltr h on 25o C and 20 r H Evaporation filter area 3 5 m Weight empty approx 24 kg Water reservoir approx 50 ltr Dimensions L 75 5 x H 62 0 x W 36 5 cm m Disconnect the mains plug before openingthe equipment 26 Technical data ...

Отзывы: