25
Relay active when no radio
signal
00 = OFF
01 = ON
Only necessary with connection to a
central air-conditioning system
00
26
Relay switch status
(Low= Relay active open
High= Relay active closed)
00 = OFF
01 = ON
Only necessary with connection to a
central air-conditioning system
00
30
Rinsing setting
31
Rinse cycle in days
00 = OFF
(manuell)
01 ... 07 days
If rinsing is existent
07
32
Water hardness setting
01 = soft
02 = medium
03 = hard
Water hardness affects the filter
change display interval
02
33
Resetting the filter
change indicator
98 = reset
The display „98 - .00” shows in how
many days the filter will have to be
changed. The display can be reset to
98 days at any time
98
34
Operation via external 00 = OFF
time switch or other 230V 01 = ON
switching mechanism
REQUIRED humidity level is fixed at
90%. The ACTUAL display shows a
constant 00%rF. The fan can be set
freely at any suitable speed
00
35
Setting/Changing interval
of the fan in auto-mode
01
… 10 min.
Dependent on the size of the room
The immersion pump can be removed from the centre
plate by turning it in the
direction indicated by the
arrow. Take particular
care when installing the
pump to ensure that the
plug connection as well as
the pump hoses and the
Y-piece, or on devices with
UV-technology the connec-
tion hoses to the V4 A-pipe,
are firmly fitted.
To prevent the development of germs, algae, mould
or bacteria and the odours they cause in the water
container of a humidifier, we recommend the use of
adequate hygiene products
such as LiQVit and Secosan.
Secosan can be placed di-
rectly in the water container.
When exchanging the water
in the reservoir, simply take
it out and the Secosan Stick
can be used again. Depend-
ing on the volume of the
18. Hygiene products