background image

 

 

 

 
 

water container, there are different 
Secosan  Products  available.  Like 
the  Secosan  Stick,  LiQVit  is  also 
designed to keep the water in your 
humidifier clean and free of bac- 
teria, algae and mould. Apart from 
that,  it  also  reduces  the  waters’ 
surface tension, which leads to an 
increased rate of dehumidification. 
Working against lime scale, it can 
also  significantly  increase  the  life- 
time of the evaporation filter.

 

 

 

The device should be cleaned of calcium (lime) de- 
posits  and  soiling every  3-4  months.  For this purpose, 
the upper section of the housing is detached, the filter 
removed  and  the  centre  plate  cleaned.  A  commer- 
cially  available  cleaning  agent  can  be  used  for  this 
purpose.  All  traces  of  the  cleaning  agent  must  be  re- 
moved (rinse thoroughly with clean water).

 

Do  not  use  benzene  or  other  solvents  that 

attack plastic.

 

The  humidifier  sh- 
ould  be  cleaned 
thoroughly  once 
a  year  (preferably 
by  our  mainte- 
nance    service).

 

Use  commercially

 

available  limescale  remover  (decalcifying  agent)  to 
remove lime residue. Then rinse thoroughly with clean 
water.  The  water  distributor  is  open  at  the  top,  easily 
accessible and should be cleaned of any residue. If 
blocked, the drain holes in the water distributor can 
be  cleaned  with  a  knitting  needle  or  similar.  While 
cleaning, check  to  ensure  there  are  no  sludge  depos- 
its in the pump hoses. If necessary, they should be 
cleaned with a narrow bottle brush or they should be 
replaced.  Should  the  equipment  remain  out  of  service 
for longer  periods, the residual water is  to be  emptied 
out, the filter is to be removed and cleaning is to be 
carried out.

 

 

 

Automatic  water  supply

 

The connection to the local water main must be made 
by a qualified specialist, i.e. a licensed installation tech- 
nician. (Please note the water supply utility’s regula- 
tions. It may be advisable to fit a back-flow stop valve.)

 

We  recommend  our  1.5-metre  long  safety  pressure 
hose for the connection between the water pipe and 
the appliance (Product no 1754).The automatic sys- 
tem for topping up the water incorporates a magnetic 
valve.  In  the  factory  the  appliance  is  set  at  automatic 
water supply at a maximum fill level of 30 litres, i.e. 
when the fill level reaches 30 litres the water supply 
is  shut  off.  If  the  water  supply  is  active,  this  is  shown 
by a running light (10-50 litre  diodes  flash on  after the 
other). The  water  supply  is  controlled  by  the  electron- 
ic  rods  in  the  water  level  display.  To  ensure  faultless 
functioning of the automatic water supply it is there- 
fore necessary for the electrode rods to be cleaned 
regularly with a sponge and freed of any deposits of 
chalk  or  dirt.  In  order  to  avoid  overfilling,  when  the  fill 
level  of  50  litres  is  reached  a  malfunction  message 
is  issued,  i.e.  the  appliance  is  automatically  switched 
off, an audible warning signal is given, and Fault Code 
04 appears in the display. If the water supply is de- 
fective and the water level does not change although 
the  magnetic  valve  is  open,  the  process  is  terminated 
and Fault Code 01 appears in the display. 

Please refer 

to  the  next  page  (Rinsing  system)  for  a  sketch  and 
the  dimensions. 

We recommend for  safety’s  sake that 

our  safety  collection  tub  (Product  no.  1752)  should  be 
used,  connected  to  our  safety  water  sensor  (Product 
no.  1757),  or  that  an  addition  external  water  valve 
should be used (Product no. 1753).

 

 

 

Water supply 

Rinsing  system  outlet

 

The  maximum  water  pressure  must  not  ex- ceed 

10 bar!

 

20. Accesoires  (optional  extras)

 

19. Cleaning

 

Содержание B500

Страница 1: ......

Страница 2: ...gy with calcium conversion cartridge B 14 Changing the UV tubes B 14 21 Parts list B 15 22 Design Exploded view drawing B 16 23 Maintenance check lists B 17 24 Correcting faults B 19 25 Installation suggestions B 20 26 Technical d a t a B 21 m Before you commission your new equip ment please read through the operating in structions Commissioning Check List Within the equipment are the accessories ...

Страница 3: ...er change indicator Electronic water level indicator Fan speed indicator Automatic fan Actual required atmospheric humidity dis play Menu in programming mode or Fault code with error message Error message display note fault code The electronic hygrostat radio sensor system auto matically controls the humidifier The required humid ity values can be set by means of the remote control m Disconnect th...

Страница 4: ...r level is indicated by light emitting diodes max 5 stages Both normal tap water and softened water can be used to operate the humidifier m Do not use distilled water Take care to fill correctly since spilt water could enter the equipment and cause a short circuit The maximum temperature of the water must not exceed 35 C The water level is sensed by copper electrodes and is indicated by LEDs on th...

Страница 5: ...n of the housing thus causing leaks m Before doing any work on the appliance always make sure it is unplugged from the wall socket In the event of a defect in the control panel it may be necessary to replace it completely Please proceed as follows 1 Raise the upper part of the housing 2 Loosen the four screws on the corners of the con trol panel and take the panel out 3 Unplug the plugs 1 2 X9 vfr...

Страница 6: ... its own speed depending on the output required It does this by measuring the changes in atmospheric humidity and increasing or decreasing the fan speed accordingly To activate the automatic fan press the side of the Fan button and hold it down until the last bar has disappeared from the indicator and the red diode with the fan symbol has gone out To deactivate it simply increase the fan speed wit...

Страница 7: ...toryadjusted to 2 14 Coding the radio sensor system Coding the sensor These appliances are coded in the factory but if two or more are used in direct proximity to one another i e less than 50 metres apart a different coding may be necessary For each slide control there are only two positions ON up and 0FF down which give 16 possible combinations Please note each appliance and its ra dio sensor a b...

Страница 8: ...s setting yourself Please refer to the section on Menu programming The following fault codes tell you what problem has occurred and what has to be done m If a fault code is displayed only the On Off button and the PROG and SET key on the re mote control unit can be used Fault code Fault What to do 01 Water tank is empty Check water level and top up if necessary Check water level diodes for dirt an...

Страница 9: ...ve humidi ty The programming process can be termi nated at any time by pressing the ON OFF button Please note however that this will result in the loss of all the changes that have been made 10 Hooter setting 11 Hooter active when tank 00 OFF empty 01 ON 01 12 Hooter active when UV 00 OFF Only at version with lamp is defective 01 ON UV C technology 01 13 Hooter active with external 00 OFF With ext...

Страница 10: ... switch or other 230V 01 ON switching mechanism REQUIRED humidity level is fixed at 90 The ACTUAL display shows a constant 00 rF The fan can be set freely at any suitable speed 00 35 Setting Changing interval of the fan in auto mode 01 10 min Dependent on the size of the room The immersion pump can be removed from the centre plate by turning it in the direction indicated by the arrow Take particul...

Страница 11: ...ection to the local water main must be made by a qualified specialist i e a licensed installation tech nician Please note the water supply utility s regula tions It may be advisable to fit a back flow stop valve We recommend our 1 5 metre long safety pressure hose for the connection between the water pipe and the appliance Product no 1754 The automatic sys tem for topping up the water incorporates...

Страница 12: ...ly removed from the clips The service life is approx 6 months which primarily depends on the dirt in the room air e g smoke and dust accumulation Air scoop with flexible hose These accessories are especially used in church or gans The scoop is fitted or screwed to the outlet of the B 500 Provided with a flexible aluminium ventila tion hose 150 mm which carries the humidified air into the critical ...

Страница 13: ...perly and insert it into the glass tube again with care The UV lamp is to be disposed of in accordance with legal requirements The UV tube has an operating life of about 5000 hours m Please take care that the quartz glass body in which the source sits is not damaged when fitting and removing the UV source All accessories can be retrofitted at any time at the factory or by an authorised dealer m In...

Страница 14: ...ypad foil 1401 Water distribution 1402 Stick on part extension left 1403 Stick on part extension right 1406 Remote control 1411 Filter rods without grooves 6 1412 Filter rods with grooves 4 1413 Clamp bracket with double nib 1500 Fan complete with motor housing and 1507 mounting parts Fan housing 1508 Sheet metal screw M 4 2 x 19 A2 4 1518 Plug body with cable 1520 Gum metal bumper M 4 1522 1 High...

Страница 15: ...22 Construction ...

Страница 16: ... residues such as lime or dust for instance by means of a needle a screwdriver or even use a vacuum cleaner for this Lift middle part of device off in upward direction Remove remaining water from the water container and clean the tub bottom part This is necessary in particular when using fresh water in order to avoid higher concent rations of residues Visual check of the copper electrode bars see ...

Страница 17: ... cartridge Lift the centre plate upwards out of the water tank lower part The UV degermination arrangement is located below the centre plate next to the pump Inspect stainless steel tube visually and remove fouling Withdraw pump hoses from the stainless steel tube and check the passage of the stainless steel tube hoses Remove fouling Take care that the quartz glass body is not damaged The lime con...

Страница 18: ...ectly installed Renew filter Check the filter seating Water degermination moni tor lamp does not light 1 UV source defect Replace UV source Device does not respond to the remote control Battery discharged or incorrectly installed Distance between remote control and device too great Check battery and replace note Reduce distance Automatic water feed no longer replenishes water 2 Safety pressure hos...

Страница 19: ... must be taken to ensure that adequately large openings are available for air intakes and outlets to ventilate the appliance Living room area Equipment in a specialist shop walk in humidor Possible uses in the museum area or in churches to protect valuable organs 25 Installation suggestions ...

Страница 20: ...ent Air flow capacity 900 m h Evaporation capacity 2 6 ltr h on 25o C and 20 r H Evaporation filter area 3 5 m Weight empty approx 24 kg Water reservoir approx 50 ltr Dimensions L 75 5 x H 62 0 x W 36 5 cm m Disconnect the mains plug before openingthe equipment 26 Technical data ...

Отзывы: