The B 500 Professional offers you the possibility of
changing the factory settings and making various set-
tings to meet your requirements.
Please proceed as follows:
1. Press the
„PROG” button on the remote control unit
„Prog“.
2.
The number „10“ will appear on the control panel
display.
3. Select one of the main menus (10, 20, or 30, see
table below).
4. Once your have reached the main menu you are
looking for, press the „SET” button to reach the re-
quired sub-menu, e.g. 11, 12, or 13.
5. Once your have reached the sub-menu you are loo-
king for, after a few seconds the display will flash
with a number such as 00, 01, or 98. By pressing
the blue „Humidity“ button (%) you can increase
the figure with
‘+’ or decrease it with ‘-‘.
6. When you have made the necessary change, sim-
ply wait for about 10 seconds. After that the display
will jump back to the standard position (showing
relative humidity) and the changes will be saved.
m
If no more settings have been made for 10
seconds the display will jump back to the s
tandard position (showing relative humidi-
ty). The programming process can be termi-
nated at any time by pressing the ON / OFF
button. Please note, however, that this will
result in the loss of all the changes that have
been made.
10
Hooter setting
11
Hooter active when tank
00 = OFF
empty
01 = ON
01
12
Hooter active when UV
00 = OFF
Only at version with
lamp is defective
01 = ON
UV-C-technology
01
13
Hooter active with external
00 = OFF
With external sensor
water sensor alarm
01 = ON
01
14
Hooter active when tank
00 = OFF
(Only in combination with automatic
content >=50 liters
01 = ON
water supply)
01
15
Hooter active when no
00 = OFF
radio signal
01 = ON
01
20
Relay setting
21
Relay active when tank
00 = OFF
Only necessary with connection to a
empty
01 = ON
central air-conditioning system
00
22
Relay active when UV lamp
00 = OFF
Only necessary with connection to a
is defective
01 = ON
central air-conditioning system
00
23
Relay active with external
00 = OFF
Only necessary with connection to a
water sensor alarm
01 = ON
central air-conditioning system
00
24
Relay active when tank
00 = OFF
Only necessary with connection to a
content >= 50 Litre
01 = ON
central air-conditioning system
00
Main Sub-
menu menu
Description
Setting
Comment
Factory
setting
16. Menu programming