HV Breakout Module – Mounting and installation
Installation Manual
16
Version 01.20 // 2021
4.3.3.1 Opening the housing
7
Fig. 4-6: HV BM 1.2, housing closed
↺
↺
↺
↺
↺
↺
↺
↺
↺
↺
↺
↺
"
Loosen the four or six Allen screws (
↺
) in the cover of the housing.
"
Remove the orange-colored cover.
Fig. 4-7: HV BM 1.1, housing opened, inner cover inserted
"
HV BM 1.1 (hardware revision A): Remove the green inner cover.
8
4.3.3.2 Intermediate step: Sliding pressure screws and springs on the HV power cable
"
If not already done, loosen and remove the pressure screws of the PG glands.
Fig. 4-8: PG gland front view (pressure screw and spring)
"
Loosen and remove the pressure screw
①
and remove the spring
②
from the PG gland.
Fig. 4-9: Sliding pressure screws and springs onto the HV power cable
"
Slide the pressure screw
①
and the spring
②
onto the HV power cable.
"
Feed the HV power cable(s) through the PG gland(s) into the housing.
7 Depending on the hardware revision, details of the measurement modules shown in Fig. 4-6 to Fig. 4-13 may vary.
8 As of hardware revision E, this work step is no longer required, as the inner cover has been integrated into the housing cover.
②
①
②
①