SIGNATURE 2 SERIES
General Specifications
RF15
RF20
RF25
RF30
RF40
Filter Media Type
Smart Blend
Filter Media Capacity (cu ft)
1.5
2.0
2.5
3.0
4.0
Reactr Tank (polyglass)
9 x 48
9 x 48
9 x 48
9 x 48
9 x 48
Mineral Tank (Vortech ™)
10 x 54
12 x 52
13 x 54
14 x 65
16 x 65
Service Flow Rate -
Continuous
2
(gpm)
5
6
8
9
11
Service Flow Rate -
Intermittent
2
(gpm)
7
8
10
11
13
Backwash Flow Rate
3
(gpm) “WF” Units
only
5.0
6.0
7.0
10.0
15.0
Gallons Used / Backwash
“WF” Units
only
100
120
140
200
300
Space Required (Reactr
™ Tank)
9 x 9 x 62
9 x 9 x 62
9 x 9 x 62
16 x 16 x 51 16 x 16 x 51
Space Required (Filter Tank)
10 x 10 x 62 12 x 12 x 60 13 x 13 x 62 14 x 14 x 73 16 x 16 x 74
Approximate Shipping Weight (lbs)
165
210
270
311
430
WARNING
Lubricants
Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants will
cause swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recommended
that Dow Corning® silicone grease be used as a lubricant for all control valves. Dow Corning® 7 Release
Compound is used in the manufacture of Chandler Systems control valves. (Part # LT-150)
Sealants
Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recom-
mended that Teflon® tape be used to seal plastic Noryl® threaded fittings.
3
Reactr Specifications
The Reactr ™ requires no chemicals for its operation. It consists of two components:
(1) Reactr ™ Tank and (2) Filter Tank. The Reactr Tank serves to oxidize and percitate iron and sulfur so
that they can later be removed by the filter. The water flows down through the mineral bed of the filter and
out of the service lines. The collected percipitates must be regularly removed from the filter by reversing
the flow of water through the filter and running to the drain. Called “Backwashing” and lasting 10 minutes,
the process expands the mineral, freeing the iron, sulfur and turbidity, which is then washed out of the filter
to the drain. It is important that the correct amount of water is available for the backwash cycle. Check
pump capacity to be certain water is available in sufficient volume to adequately backwash the equipment
at a specified rate.