SIGNATURE 2 SERIES
Master Programming Mode
Master Programming Mode
To enter Master Programming Mode, press and hold both buttons for 5 seconds.
Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is
NOT
necessary to enter Master Programming Mode.
1. Regeneration Time ( r )
Example
(
r 12A
)
- The time of day at which backwash may take place is designated by the letter “
r
”.
- Default regeneration time settings
is 12a
- The first display digit indicates A.M. or P.M. To change the value, press the
Set/Change
button.
- Press
Menu/Enter
button to accept the value and move to the next digit.
- The second and third display digits indicate the hour at which the backwash will occur.
- Change the digits with the
Set/Change
button and accept with the
Menu/Enter
button.
- After the entire display flashes, press the
Menu/Enter
button to move to the next menu item.
2.
Regeneration Cycle Step Times (Steps 1, 2, 3)
Example
(
3 - 10
)
- The next 4 displays set the duration of time in minutes for each backwash cycle step.
- The step number which is currently modifiable is indicated on the far left of the display screen.
- The number of minutes allotted for the selected backwash step is displayed on the far right.
- Change the digit values using the
Set/Change
and
Menu/Enter
buttons as described above.
3.
Bluetooth Enabled
BE - 1
(ON)
BE - 0
(OFF)
4.
Bluetooth Password
BBPP
is displayed for one second, then password is displayed.
5.
To Exit the Master Programming Mode, press the
Menu/Enter
button until time of day returns.
Note
: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.
10
Содержание REACTR RF15
Страница 1: ...SIGNATURE 2 SERIES Signature 2 Series Reactr Installation Operation Manual...
Страница 19: ...SIGNATURE 2 SERIES...